Popcorn Topping Dispenser
and Base
Model Series 2396 and 2495
Page 12
gmpopcorn.com
Additional Controls
—
Photo-Eye Units Only
TIMED SWITCH
Two modes are selectable (Timed and Not Timed). In either mode, sensor must detect
popcorn for 0.5 sec. before pump is automatically activated.
Note:
To switch between Timed and Not Timed Modes, power the unit OFF for the mode
change to take effect.
Timed Mode
–
The pump turns on for a pre-determined length of time when photo-eye
detects a cup of popcorn. To adjust time, see Adjusting Dispense Settings section.
Note:
The pump stops if popcorn is removed prematurely (if popcorn is brought
back within one second, the timer will resume and finish the timing period).
Not Timed Mode
–
The pump
runs continuously
as long as the photo-eye detects a cup
of popcorn.
PHOTO-EYE SENSOR (Auto-Dispense, if equipped):
Photo-eye must detect popcorn within
about 5 inches (13 cm) of the sensor for 0.5 sec. before pump is automatically activated
(see image below for sensor indicator lights).
Note:
A slight delay is required after the popcorn is removed for the sensor to reactivate.
When wiping off the unit, shiny objects such as a watch can activate the photo-eye
at distances greater than 5 inches.
PUMP SPEED ADJUSTMENT:
Use adjustment to set how
fast
topping is dispensed (see
Adjusting Dispense Settings on next page).
DISPENSE TIME ADJUSTMENT (Auto-Dispense)
: Use adjustment to set how
long
topping is
dispensed (settable from 3.0 to 9.4 sec.) (see Adjusting Dispense Settings on next page).
Green Indicator
= sensor ready
Amber Indicator
= product detected
Photo-eye Sensor
(with
Red
indicator beam)
Photo-eye Sensor
Adjustment Panel
(use a small flat screwdriver to adjust Pump Speed or Time)
Pump Speed
Adjustment
Dispense Time
Adjustment
Timed
Switch