2.4.2.2
THE STATUS OF THE SE1 AND SE2 CONTACTS (2CH /S)
SE1
SE2
S
YSTEM STATUS
Close
(
ON
)
Close
(
ON
)
In
service
Close
(
ON
)
Open
(
OFF
)
Out of
order
Open
(
OFF
)
Close
(
ON
)
Out of
order
2.4.3
CONNECTION MOTOR/PUMP AND ACCESSORIES
Connect the motor and the installed accessories (eg: fluid heater, fluid thermostat, motor thermistors, etc.),
following the instructions of the power unit / tank manual in accordance with the electrical characteristics
of the system.
2.4.4
SLOWDOWN DISTANCES AND MAGNETS
Rated speed (V
N
)
[m/s]
<0,30
<0,40
<0,50
<0,60
<0,70
<0,80
<0,90
<1,00
Upward (C-E - D
RAL,S
)
[m]
0,25
0,35
0,45
0,60
0,80
1,00
-
-
Downward (G-I - D
RAL,D
) [m]
0,35
0,45
0,55
0,70
0,90
1,10
1,30
1,50
The distance of the deceleration sensor (D