D
ISTRIBUTOR
3010
I
NSTALLATION
,
U
SE AND
M
AINTENANCE
ENG
3 / 28
10991838
EN
-
0.02
-
04.02.2021
INDEX
0 GENERAL INFORMATIONS
5
0.1
I
NTRODUCTORY INFORMATION
5
0.1.1
D
EFINITIONS
5
0.1.2
M
AIN STANDARDS OF REFERENCE
5
0.1.3
D
OCUMENTATION FOR INSTALLATION
5
0.1.4
T
ERMS AND SYMBOLS USED
6
0.2
S
AFETY DURING INSTALLATION
6
0.2.1
T
OOLING
6
0.3
G
ENERAL PROVISIONS
6
1 FEATURES AND REQUIREMENTS
7
1.1
T
HE
3010
2CH
A3
DISTRIBUTOR
7
1.2
T
HE FLUID
7
1.3
H
OW THE
3100
2CH
A3
SYSTEM WORKS
7
1.4
M
AIN FEATURES
7
2 INSTALLATION OPERATIONS
8
2.1
H
YDRAULIC CONNECTIONS
8
2.1.1
O
VERALL DIMENSIONS
8
2.1.1.1
D
ISTRIBUTOR
1”¼
8
2.1.2
I
NPUT AND OUTPUT
-
POWER UNIT SIDE
8
2.1.2.1
D
ISTRIBUTOR
1”
¼
E
1”
½
8
2.2
H
YDRAULIC CIRCUITS
9
2.2.1
D
ISTRIBUTOR
3010
2CH
A3
9
2.2.1.1
U
PWARD AND
D
OWNWARD GRAPH
9
2.2.1.2
H
YDRAULIC SCHEME
9
2.2.2
D
ISTRIBUTOR
3010
2CH
A3
/
S
10
2.2.2.1
U
PWARD AND
D
OWNWARD GRAPH
10
2.2.2.2
H
YDRAULIC SCHEME
10
2.3
P
RELIMINARY OPERATIONS TO CONNECTION
11
2.4
E
LECTRICAL CONNECTIONS
11
2.4.1
C
ONTROL PANEL REQUIREMENTS
11
2.4.2
HOW THE
SE1
AND
SE2
CONTACTS WORK
11
2.4.2.1
T
HE STATUS OF THE
SE1
AND
SE2
CONTACTS
(2CH)
11
2.4.2.2
T
HE STATUS OF THE
SE1
AND
SE2
CONTACTS
(2CH
/S)
12
2.4.3
C
ONNECTION
M
OTOR
/
PUMP AND ACCESSORIES
12
2.4.4
S
LOWDOWN DISTANCES AND MAGNETS
12
2.5
C
ONNECTION OF HYDRAULIC PIPES
13
2.5.1
C
ONNECTION WITH HOSE
13
2.5.2
C
ONNECTION WITH A RIGID PIPE
13
3 ADJUSTMENTS, CHECKS AND TESTS
14
3.1
J
ACKS ADJUSTMENTS
14
3.1.1
R
UPTURE
V
ALVE
14
3.2
D
ISTRIBUTOR ADJUSTMENTS
14
3.2.1
A
DJUSTMENT OF THE MAXIMUM PRESSURE VALVE
(VS)
14
3.2.2
A
DJUSTMENT OF THE ACCELERATION
14
3.2.3
A
DJUSTMENT OF THE LEVELLING SPEED
(
LOW SPEED
)
15
3.2.4
A
DJUSTMENT OF THE UPWARD SPEED
(
HIGH SPEED
)
15
3.2.5
A
DJUSTMENT OF THE DOWNWARD SPEED
(
HIGH SPEED
)
15
3.2.6
A
DJUSTMENT OF THE UPWARD AND DOWNWARD DECELERATION
16
3.2.7
A
DJUSTMENT OF THE PRESSURE ON THE RAM ON
VSMA
16
3.2.8
A
DJUSTMENT OF THE MAXIMUM PRESSURE VALVE
ON
THE
PAM
(VS
10)
17
3.2.9
R
EMOTE HAND PUMP FILLING
17
3.3
E
XAMINATIONS AND TESTS BEFORE PUTTING INTO SERVICE
17
3.3.1
R
UPTURE
V
ALVE
(VC)
[EN81-20
§6.3.8]
17
3.3.2
R
ESTRICTOR
/
ONE
-
WAY RESTRICTOR
(VC)
[EN81-20
§6.3.9]
18
3.3.3
P
RESSURE
T
EST
[EN81-20
§6.3.10]
18
3.3.4
P
ROTECTION AGAINST UNINTENDED MOUVEMENT
[EN81-20
§6.3.13]
18
3.3.4.1
P
RELIMINARY
R
EQUIREMENTS
18
3.3.5
E
NERGY STATUS ZERO
18
4 MAINTENANCE
19
4.1
P
ROGRAMMED MAINTENANCE
19
4.2
P
ERIODICAL MAINTENANCE AND CHECKS TABLE
19
4.3
M
AINTENANCE OPERATIONS
20
4.3.1
S
TANDARD TIGHTENING TORQUES
21
4.4
D
ISPOSAL OF MATERIALS
21