FAULTS
5.1
TROUBLESHOOTING
In this chapter, the following conditions are considered verified:
-
the motor / pump unit is correctly powered and moves in the right direction of rotation
-
the shut-off valve (R/S) is open and the delivery line has no leaks
(
PIPING
,
RUPTURE VALVE AND PISTON
)
-
the safety gear of the system (if present) has not intervened;
-
the minimum static pressure allows the downward movement of the system (car).
I. The system does not start upward and downward
D
ETECTED STATUS
The control panel, with the car parked at floor, detects the contacts SE1 and SE2 not both closed.
Using a tester, check their effective status on the contacts and proceed as follows.
P
OSSIBLE CAUSE
P
OSSIBLE SOLUTION
Contacts SE1 and SE2 are both closed
WITH THE CAR PARKED AT FLOOR
Check the cables and connections to the contacts.
The wiring of the contacts to the control panel
has at least one interruption
Restore continuity by replacing or repairing the line that
has interruptions.
The wiring of the contacts to the control panel
has no interruptions
The control panel does not process correctly the signals
coming from contacts SE1 and SE2.
Identify the applicable solution in the manual of the
control panel and electrical part.
Pressure switch SE1 (Pressure transducer) is open with the car parked at floor
The VMD coil is powered
Verify why the control panel does not disconnect the
VMD coil power supply. Set the control panel mode to
disconnect the coil, when the car is parked at floor.
The VMD cursor does not close properly
Check that the ball closes and moves correctly inside its
seat (no fluid leakages).
Clean both if necessary.
The non-return valve (VRP) does not close
correctly.
Put the system into the zero-energy status (§3.3.5)
(
SWITCH OFF THE CURRENT
,
CLOSE THE GATE
(
R
/
S
),
RELEASE
THE PRESSURE
).
Remove the VRP shutter and check that the sealing
seats are clean. If the gasket is damaged and / or
worn, replace it. Reassemble the shutter checking that
it slides well into its seat.
The pressure switch SE1 is faulty
If VMD and VRP are properly closed and SE1 remains
open. The SE1 pressure switch is faulty and must be
replaced.
The SE2 switch is open with the car parked at floor
The VMP 2CH coil is powered
Verify why the control panel does not disconnect the
VMP 2CH coil power supply. Set the control panel
mode to disconnect the coil, when the car is parked at
floor.
The VMP 2CH cursor does not close properly
Check that the ball closes and moves correctly inside its
seat.
Clean both if necessary.
The VB shutter does not close properly
Put the system into the zero-energy status (§3.3.5)
(
SWITCH OFF THE CURRENT
,
CLOSE THE GATE
(
R
/
S
),
RELEASE
THE PRESSURE
).
Remove the shutter VB and check the integrity and
cleanliness of the sliding seats.
Check that the feeler that activates the contact moves
and returns to the correct position.
Reassemble the shutter checking that it slides well into its
seat.