36
9.2 About the control unit
The resetting to factory settings is triggered with the control unit. The settings of
the detection unit are reset to the factory settings and the pairing between control
unit and detection unit is deleted.
9.3 About the digital input
The resetting to factory settings is triggered with the digital input. The settings of
the detection unit are reset to the factory settings.
The detection unit and the control unit were reset to factory settings.
Now you can re-commission the system.
See 8.1 'Storing the admin finger and establishing normal operation'
See 7 'Establishing normal operation and use of the finger scanner with app'
The detection unit and the control unit were reset to factory settings.
Now you can re-commission the system.
See 8.1 'Storing the admin finger and establishing normal operation'
See 7 'Establishing normal operation and use of the finger scanner with app'
Action
Description
Display
Press the button with the control
stick (mini CU) or with a small
screwdriver
(micro CU) for at least 4 s.
Status LED of the finger scanner
blinks blue
Upper status LED of the mini CU
blinks orange/green and/or
LED of the micro CU blinks
green slowly.
Instructions
1.
Disconnect the micro from the mains voltage.
2.
Press and hold the door button or close the pins of the digital input briefly and
hold them in short-circuit.
3.
Connect the micro to the mains voltage.
4.
Hold the door button or hold the pins of the digital input in short-circuit for at least 5 s.
5.
Release the door button or remove the short-circuit. Press the door button or close
the pins of the digital input briefly for at least 500 ms within 5 s.