background image

www.glp.de

 

 

20  

Highlander Wash Quick Start and Safety Manual 

 

Release the tilt lock, check the clearance around the head and make sure that 
nobody is looking directly at the fixture. Then apply power to the power input cable. 

Installing power connectors on the input cable 

It is possible to install a cord cap / mains power plug that is suitable for your local 
convenience receptacles / power sockets on the supplied power input cable. If you do 
this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a 
connection to ground / earth and that it has an integral cable grip. Follow the cord cap 
/ plug manufacturer’s assembly instructions. 
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow 
the instructions given on the Neutrik website at www.neutrik.com. 
Respect the color coding used in the supplied power cable and in your local mains 
power wiring system. US and EU systems use the color coding shown below: 

 

 

Live or L 

Neutral or N 

Ground / Earth or   

US system 

Black White 

Green 

EU system 

Brown Blue  Yellow/green 

 

Setting up fixture control 

The Highlander Wash can be controlled via USITT512 DMX over a standard DMX cable 
link, Art-Net network or sACN network. 
If you would like advice with planning and installing a suitable control link, your GLP 

supplier will be happy to provide assistance. 

DMX 

See ‘Overview’ on page 13. The fixture has 5-pin XLR IN and THRU sockets for connection 
to a DMX cable link. 
Connectors use standard DMX pinout: 

 

Pin 1 = Ground  

 

Pin 2 = Negative / data cold 

 

Pin 3 = Positive / data hot. 

 

Pins 4 and 5 are not used.

 

To configure the fixture for DMX control over a DMX cable link, open the menus in the 
fixture’s control panel and make the following adjustments: 

 

In the first menu (root menu), set the fixture’s DMX address to a suitable address. 

 

In the 

Control Protocol

 menu, set the control protocol to 

DMX

 (the default setting). 

These settings will not be affected if you apply a 

Load Default Settings

 command in the 

fixture’s control panel, but they will be returned to factory defaults if you apply a 

Load 

Factory Backup

 command in the fixture’s control panel. 

To link fixtures in cabled DMX daisy-chains using their XLR connectors, use certified DMX 
cable only.  

PRELIMINARY

Содержание Highlander Wash

Страница 1: ...Fixture software version 26 Quick Start and Safety Manual P R E L I M I N A R Y...

Страница 2: ...affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the inf...

Страница 3: ...age from dust and airborne particles 12 Transportation and storage 12 Overview 13 Overview of features 14 Lamp 14 Control panel and display 14 Base and rigging options 14 Preparation for use 15 Includ...

Страница 4: ...Adjusting the lamp 26 Main fuse 26 Lubrication 26 GLP Service and Support 26 Technical specifications 28 Dimensions 31 P R E L I M I N A R Y...

Страница 5: ...The User Manual explains features and control of Highlander Wash fixtures The Highlander Wash DMX Channel Index available for download from www glp de The Channel Index is a separate guide to the DMX...

Страница 6: ...ure Refer all repairs and any service operation not described in this manual to a technician authorized by GLP Read and follow the user documentation for all additional equipment Electrical safety Do...

Страница 7: ...m the fixture is powerful enough to cause burns or fire in illuminated objects at close range Keep all combustible materials e g fabric wood paper at least 1 m 3 3 ft away from the fixture Ensure that...

Страница 8: ...the person s first seizure or if the person is injured While waiting for help to arrive protect the affected person from injuring themselves on hard or sharp objects If necessary move the person to a...

Страница 9: ...nd only with hardware that is specifically designed approved and rated for its purpose Do not use a safety cable as the primary means of support Check that installation hardware is in perfect conditio...

Страница 10: ...whenever installing servicing or moving the fixture If the fixture becomes damaged stop using it immediately and disconnect it from power Do not attempt to use a fixture that is obviously damaged Do...

Страница 11: ...nual Oils solvents and other chemicals commonly used for cleaning can damage the lens coatings and surfaces Use only original spare parts Do not make any structural modifications to the fixture or you...

Страница 12: ...ctly clean Wear clean gloves when changing the lamp Avoiding damage from dust and airborne particles Carry out regular visual inspections of every fixture to make sure that there is no accumulation of...

Страница 13: ...Cooling vent H Safety cable attachment point I Floor stand J Mini base K Cooling vent L Backlit LCD display M Quick Menu ESC button N Jog wheel O ENTER button P DMX OUT THRU 5 pin XLR Q Fuseholder R...

Страница 14: ...e the lamp before it reaches its rated lifetime Lamp power The lamp can be operated at two power levels At the NORMAL power setting the lamp runs at 1400 W At the ECO power setting the lamp runs at 10...

Страница 15: ...xture s floor stand supplied to the fixture using the camlock bracket attachment points in the base of the fixture Lift the fixture straight up out of the flightcase turn it upside down and place it o...

Страница 16: ...afety cable In any location where the fixture can cause injury or damage if it falls secure it with a safety cable that is approved as a secondary attachment for the weight of the fixture To secure th...

Страница 17: ...aximum 11 mm 0 43 in into the base of the fixture when tightened See Figure 4 Fasten the bolts or screws through the half coupler clamps and into holes A in the base of the fixture so that the clamps...

Страница 18: ...n page 16 Make sure that the head will not collide with another fixture or any other object when it moves through its full pan and tilt ranges Sideways Mounting For sideways mounting i e mounting with...

Страница 19: ...at nobody will be looking directly at the fixture if it lights up suddenly Powering the fixture off Turn off the lamp but leave the fixture connected to power for 30 minutes before powering the fixtur...

Страница 20: ...en EU system Brown Blue Yellow green Setting up fixture control The Highlander Wash can be controlled via USITT512 DMX over a standard DMX cable link Art Net network or sACN network If you would like...

Страница 21: ...t it is possible to transmit DMX data as broadcast or unicast packages via Art Net If a large number of universes more than 30 is broadcast data loss can occur If you suspect that this is happening co...

Страница 22: ...For guidance on using the Highlander Wash see the latest version of the fixture s User Manual available for download from www glp de Check that the software version given at the front of the user manu...

Страница 23: ...o prevent the fixture from cooling correctly and this will reduce the fixture s lifetime The rate of dirt buildup will vary depending on environmental factors such as airborne dust use of smoke machin...

Страница 24: ...losion replace the lamp before it reaches the end of its lifetime Do not touch the lamp with bare fingers If you get any grease or oil on the lamp clean it carefully with an alcohol wipe and wipe it d...

Страница 25: ...up the bayonet mount pins with the pin slots in the lampholder Insert the lamp into the lampholder and twist clockwise until locked into position Do not touch the glass bulb of the lamp with your fin...

Страница 26: ...n right and see Overview on page 13 The main fuse sits in a fuseholder in the base If the fixture appears to be completely shut down even though power is applied the main fuse may have blown Disconnec...

Страница 27: ...German Light Products Highlander Wash Quick Start and Safety Manual 27 GLP U K 44 1392 690140 GLP Asia 852 3151 7730 GLP Nordic 46 737 57 11 40 P R E L I M I N A R Y...

Страница 28: ...us linking system Output lens diameter 230 mm 9 in Movement Resolution 8 16 bit Position feedback Yes Pan 640 Tilt 262 Effect movement Fast Normal and Smooth performance options Control Pan and tilt c...

Страница 29: ...temperature controlled or constant fan options Max ambient temperature 45 C 115 F Min ambient temperature 5 C 41 F Max surface temperature at 40 C ambient 100 C 212 F Total heat dissipation at 230 V 1...

Страница 30: ...ht Width head at max horizontal extension 724 mm 28 6 in Width across yoke 492 mm 19 4 in Height head vertical 773 mm 30 5 in Height head at max vertical extension 794 mm 31 3 in Height incl floor sta...

Страница 31: ...German Light Products Highlander Wash Quick Start and Safety Manual 31 Dimensions Dimensions are given in millimeters P R E L I M I N A R Y...

Страница 32: ...P R E L I M I N A R Y...

Страница 33: ...P R E L I M I N A R Y...

Страница 34: ...P R E L I M I N A R Y...

Страница 35: ...P R E L I M I N A R Y...

Страница 36: ...P R E L I M I N A R Y...

Отзывы: