26
220692C
26
SECTION
Installation
6
s t e p
14
s t e p
15
s t e p
16
3045
ELECTRICAL
CONNECTION(S)
Secure the flue assembly to the boiler,
using the previously fitted dogpoint
screws noting that these are keyhole
fixings.
Take the beige/grey sealant from the
loose items pack and place firmly
around the internal spigot of the flue
manifold.
Make sure of the correct location of the
flue and boiler.
If removed, refit the control box/
combustion chamber by reversing the
instructions in Section 6, step 18 and
Section 10, steps 3,5,6,7,8 and 9.
Loosely fit one extended brass
fluehood/fan assembly screw to the
heat exchanger on the side that the
flue exits. Slide the fluehood/fan
assembly flange under this extended
brass screw whilst turning the assembly
to enable engagement of the fan outlet
extension onto the flue manifold spigot.
After fitting the fan outlet extension to
the spigot smooth the sealant over the
joint.
When correctly located, secure the
assembly by fitting the other extended
brass screw and tighten both down.
Reconnect the violet and red
electrical connections to the fan, the
polarity of the connections is not
important.
Reconnect the air pressure switch
tubes.
BEIGE/GREY
SEALANT
FAN
OUTLET
EXTENTION
EXTENDED BRASS
FLUE HOOD FAN
ASSEMBLY SCREW
FLUE HOOD/
FAN ASSEMBLY
AIR PRESSURE
SWITCH TUBES
FAN
OUTLET
EXTENSION
FLUE
MANIFOLD
SPIGOT
CLEAR
RED