SECTION
Flue Installation
5
s t e p
14
3039
s t e p
16
s t e p
15
Wall Thickness up to
300mm
Fit the self adhesive foam seal provided
in the loose items pack around the air
duct/terminal at the position shown.
Wall Thickness over
300mm
Fix the self adhesive foam seal around
the air duct/terminal such that, when
installed, the seal will be within the
wall sleeve.
If the boiler is not to be fitted for
sometime cover the hole in the wall.
On all installations push the flue
assembly into and through the wall
sleeve and hole such that it is within
the wall sleeve and does not stick out
into the room. Do not push the flue
assembly too far into the hole as it has
to be pulled back into the boiler and
secured to the keyhole fixings.
Note: That the foam seal is a tight fit in
the wall sleeve, so either the wall
sleeve will need to be rigidly fixed in
the wall, that is, the cement has fully
set or it can be held from the other side
whilst inserting the flue assembly.
FOAM SEAL
Q-25mm
FOAM SEAL
10mm
Q
Q
WALL
SLEEVE