![Glow-worm Space Saver K.F.B 60 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/glow-worm/space-saver-k-f-b-60/space-saver-k-f-b-60_installation-and-servicing-instructions_2234552023.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
23
220692C
23
SECTION
s t e p
6
Installation
3042
7
s t e p
8
s t e p
17
Continue at
Fit fan/fluehood assembly by
engaging the fan outlet extension
over the flue manifold spigot.
Secure the fluehood assembly to the
heat exchanger with the screws
previously removed.
If removed, refit the control box/
combustion chamber by reversing the
instructions in Section 6, step 18 and
Section 10, steps 3,5,6,7,8 and 9.
Reconnect the violet and red electrical
connections to the fan, the polarity of
the connections is not important.
Reconnect the air pressure switch tubes
as shown.
FLUE
MANIFOLD
SPIGOT
FAN
OUTLET
EXTENTION
ELECTRICAL CONNECTIONS
AIR
PRESSURE
SWITCH
TUBES
RED
WHITE
RED