![Glow-worm Space Saver K.F.B 60 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/glow-worm/space-saver-k-f-b-60/space-saver-k-f-b-60_installation-and-servicing-instructions_2234552005.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
5
220692C
5
SECTION
General
1
Range Rating
The boiler is range rated and may be
adjusted to suit individual system
requirements, refer to the relevant
column of the table.
Data Table
in wg
5.6
5.9
mbar
14.0
14.6
Btu/h
50000
60000
kW
14.66
17.59
in wg
4.9
5.2
mbar
12.2
13.0
in wg
4.2
4.6
mbar
10.6
11.4
Btu/h
60000
70000
kW
17.59
20.52
Btu/h
55000
65000
kW
16.12
19.05
Nominal
min
Heat
med
Input
max
(Gross)
Nominal
min
Heat
med
Ouput
max
Burner
min
Setting
med
Pressure
max
Space Saver
Space Saver
Range Rating
K.F.B
K.F.B
60
70
Btu/h
70064
84416
kW
20.54
24.74
Btu/h
75000
89709
kW
21.98
26.29
Btu/h
64935
78947
kW
19.03
23.14
Data Label Position
3038
Space Saver
Space Saver
Model
K.F.B
K.F.B
60
70
Lifting
32.4kg
32.4kg
Weight
(71.4lb)
(71.4lb)
Total
46.1kg
46.1kg
Weight (dry)*
(101.6lb)
(101.6lb)
Water
2.13 litres
2.13 litres
Content
(0.47 gal)
(0.47 gal)
Gas
Rc
1
/
2
Rc
1
/
2
Connection
(
1
/
2
" BSPT)
(
1
/
2
" BSPT)
Water
28mm
28mm
Connection
Compression
Compression
Electrical
240V~50Hz fused 3A max
supply
Internal
Fuse to BS4265 sheet 2. Type F1A
Fuse Rating
Power rating
55W
* Note: The weight of the water is negligible
Space Saver K.F.B 70
G.C. Number 41 319 12
Space Saver K.F.B 60
G.C. Number 41 319 11