SECTION
s t e p
5
Flue Installation
s t e p
1
s t e p
3
5.5mm DRILL SIZE
No. 10x1
1
/
2
in
SCREW
WALLPLUG
300mm MAX
LENGTH
Q
Q
115mm
MINIMUM
HOLE
WALLPLATE/
TEMPLATE
2892
2
If the wall thickness “Q” is less than
300mm cut the wall sleeve to the
required length.
Fit the wall sleeve.
Make good around the wall sleeve at
both internal and external wall faces
(through the wall sleeve if internal
access only is available).
If the wall thickness “Q” is greater than
300mm the wall sleeve must be fitted
flush with the INSIDE wall face. If the
inner end of the sleeve sticks out into a
cavity then, if desired, the wall sleeve
can be trimmed back to the depth of the
inner skin of the brickwork. Make good
at the internal wall face, leave the
external wall face until later.
Rear Flue Application
Having selected the boiler location
with due regard to the terminal
position;
Using an adhesive tape temporarily
position the wallplate/template on the
wall.
Mark out the centre and cut the hole for
the flue using, preferably, a 115mm
minimum core drill.
Reposition the wallplate/template
ensuring alignment with the flue hole.
Mark the top and bottom boiler
mounting hole positions.
Remove wallplate/template, drill holes
and then secure wallplate/template to the
wall with the fittings provided in the
loose items pack.