background image

ON/OFF SWITCH

INTENDED USE

50586

SPECIFICATION

FEATURES

SAVE THESE INSTRUCTIONS

• Replace existing on/off or dimmer switches and make them smart

• Manually or remotely control your wall switch with the Amazon Alexa app

• Pair with Amazon echo to control your switch through voice commands

• Set schedules and control your switch from anywhere 

 

• This product is intended to be used as a wall switch to control incandescent and Led light bulbs as part of 

permanent fixtures. It is intended to replace a standard switch receptacle. It can be connected and controlled 
through a WI-FI connection with the Amazon Alexa app or other external Alexa built-in devices. 

• Intended for household use only
• Intended to be used in dry indoor areas only 

 

Switch type

Single pole + 3-Way

120Vac / 60Hz

Wiring

Maximum Load

Standby Power

Start up Time

Wireless Control Module

Status Indicator

On/Off switch

Main unit

<0.5W

<1 second

Wi-Fi 2.4GHz, IEEE 802.11 b/g/n

Bluetooth Low Energy

Does not support 5GHz networks, 

BLE only for pairing the phone and device

Rated input voltage

108-132Vac

Incandescent: 600W max.

LED: 150W max.

Input Voltage Range

Wire to wire connection

Neutral wire is required 

Thank you for selecting Globe 
as your smart home solution. 
With proper care, this product will 
provide years of pleasure and enjoyment. 

Step-by-step

Product Instruction Video

Scan with your

mobile device

This Smart Switch is warranted to last 1 year from the date of purchase. If it fails before that time, we will replace it. Send Globe Electric the 
Smart Switch, proof of purchase and register receipt along with your complete name and address. See caution text for proper use.  This 
warranty is void if this product is misused in any way. This replacement is the sole remedy available and liability for incidental or consequential 
damage is expressly excluded.

For use only in 120V/60HZ circuits. Risk of electrical shock. Do not open, no user-serviceable parts inside. This device is not intended for use 
with emergency exit fixtures or emergency exit lights, photocells and electronic timers. Do not use where directly exposed to water. If this 
situation is undesirable for the application, follow the manufacturer’s instructions for replacing the device. Minimum operating temperature is 
-20°C (-4°F).

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any 
changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. 

RF Exposure 

The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This device should be installed and 
operated with minimum distance 20cm between the radiator & your body. 

User Manual Notice for License Exempt Radio Apparatus 

This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this 
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired 
operation of the device. CAN ICES-005 (B).

Radiation Exposure Statement: 

This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and 
operated with minimum distance 20cm between the radiator & your body.

WARNING: 

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s 

authority to  operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15  of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 
installation.

FCC Responsible party

Globe Electric

15301 Shoemaker Ave, Norwalk, CA 90650

www.globe-electric.com

Most electrical accidents are caused by carelessness or ignorance. If you combine a basic knowledge of electricity, 

a healthy respect for it, and a dose of common sense, you can safely tackle many household electrical repairs. 

Here are some basic guidelines for working with electricity:

• Before working on a circuit, go to the main service panel and remove the fuse or trip the breaker that controls 

that circuit. Tape a sign to the panel warning others to leave the circuit alone while you work.

• Before touching any wire, use a voltage tester to make sure it’s not live. Whenever you check for voltage in a receptacle, 
check both outlets—each may be controlled by a separate wiring circuit. 

• To protect children, place safety covers over any unused outlets.

• Always work with enough light to see what you are doing; it’s easy to make mistakes when you’re working in dim light.

Before assembling your smart switch fixture, TURN OFF THE POWER and consult a qualified licensed electrician.

Содержание 50586

Страница 1: ...Smart User Guide ON OFF SWITCH...

Страница 2: ...cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any changes or modi cations not expressly approved by the...

Страница 3: ...1s Press and hold power button 10s Red and Green blinking alternately Solid Green for 3 seconds WARNING Improper wiring of any electrical device can cause re serious injury or death Always consult a q...

Страница 4: ...ral white x2 d Load red 4 Disconnect the wiring from the old switch 5 Connect the WI FI on off switch to the existing wiring a Connect Ground Green A wire on the switch to the Ground green wire from t...

Страница 5: ...the WI FI on off switch to the existing wiring a Connect Ground Green A wire on the switch to the Ground green wire from the standard switch then to the Ground Green wire from the breaker box b Connec...

Страница 6: ...re of both switches to the Ground green wire from the breaker box 2 Connect the Line Black D wire of both switches to the Line Black wire from the breaker box 3 Connect the Neutral White B wire on the...

Страница 7: ...rk perform a factory reset by following the instructions below 1 Turn the device ON 2 Press and hold the ON OFF button down for 10 seconds 3 Let go of the button once the light is ashing RED and GREEN...

Страница 8: ...Smart User Guide INTERRUPTEUR MARCHE ARR T...

Страница 9: ...n peut tre assur par l utilisateur Ne convient pas aux voyants et lampes de sortie d urgence aux r cepteurs photo lectriques ni aux minuteries lectroniques Ne pas utiliser dans un endroit o il y a ris...

Страница 10: ...ouge et vert clignotant Vert xe pendant 3 secondes ATTENTION Le c blage inad quat de tout appareil lectrique pourrait occasionner un incendie des blessures graves ou la mort Veillez toujours consulter...

Страница 11: ...phase noir b 1 l de mise la terre vert ou jaune vert c 2 ls neutres blanc d 1 l de charge rouge 4 D connectez le c blage de l ancien bo tier 5 Connecter l interrupteur Wi Fi aux ls existants a Connec...

Страница 12: ...c blage de l ancien bo tier 5 Connecter l interrupteur Wi Fi aux ls existants a Connecter le l de mise la terre vert A de l interrupteur intelligent celui de l interrupteur standard puis celui du pann...

Страница 13: ...dateur Wi Fi aux ls existants a Connecter le l de mise la terre vert a des deux interrupteurs celui du panneau lectrique b Connecter les ls de phase noir D des deux interrupteurs celui du panneau lect...

Страница 14: ...ans code barres 2D R initialisation de l appareil En cas de probl me durant la con guration ou si l appareil tait d j connect un autre r seau r initialiser l appareil selon les instructions suivantes...

Страница 15: ...enced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this d...

Отзывы: