background image

EN

17

•Clean the 

fi

 lter(s) at least once per month.

•Check to make sure you have proper circulation throughout your 
spa water system.
•Have spa users bathe before entering the spa water.

SPA LEVELING PREPARATION 

When the Spa is positioned outside it is preferable to provide 
a concrete platform. Other options are brick, stepping stone, 
or blocks. It is important to note that soft surfaces, even when 
stepping stones are used to evenly distribute the weight of the 
spa, will have a tendency to settle, thus resulting in an unleveled 
spa. 

NOTE: Placing the Spa directly on the grass or on gravel 
may increase the amount of debris which is inadvertently 
brought into the spa water and may cause harm to your 
equipment as well as the spa surface, which are not covered 
under warranty.

0

Stepping stones or brick may settle causing the spa to be unlevel.

CAUTION: adjust the central feet of Spa to ensure that they 
rest properly on the 

fl

 oor. 

Mawi Spa 175/200

STOP

NOTE: the cords to adjust the feet have been positioned 
near the pumps.

  

SPA COVER INSTALLATION

Place the cover squarely on the spa.

NOTE: Keeping the cover in place any time the spa is not 
in use will reduce the amount of time the heater operates, 
thereby minimizing operating costs. 

DANGER.RISK OF INJURY.
•Never leave a spa uncovered or unattended.
•Do not stand, sit, or lie on the cover.

NOTE: please remove coussins (if any) before installing 
the cover.

TECHNICAL COMPARTMENT CONNECTIONS

ALL THE PLUMBING WORKS MUST BE CARRIED OUT BY A 
QUALIFIED PLUMBING INSTALLER.

ATTENTION: the hydraulic connection must be made to the 
mains water network, which is why it must be carried out in 
compliance with anti-pollution protection standards. Please 
contact local authorities for more information on the rules 
governing the discharge of chemically treated water.

Proceed with the connection

 C1 - F1 

on the thermostatic mixer 

located under the edge of the tub and with the tub drain 

O1 

(see 

chapter “CONNECTIONS DIAGRAM” and product technical 
datasheet); then connect the sand 

fi

 lter (optional) and the heat 

exchanger (optional), see chapter “SYSTEMS”.

ATTENTION: before starting the spa, test the system to check 
the hydraulic connections.

The power box must be connected at the point 

C.V.

 (see 

installation set-up).Connecting the spa to an improperly wired 
circuit will negate many of the spa’s safety features. Improper 
wiring may also cause electrocution, risk of 

fi

 re, and other risks 

of injuries. Please read and follow the electrical installation 
requirements!
SPA MUST BE WIRED IN ACCORDANCE WITH ALL 
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. 
ALL ELECTRICAL WORK SHOULDBE DONE BY AN 
EXPERIENCED, LICENSED ELECTRICIAN. WE RECOMMEND 
THE USE OF APPROPRIATE ELECTRICAL CONDUIT, 
FITTINGS, AND WIRE FORALL CIRCUITS.The Spa require a 
16 amp, single phase, 220-230 volt, three wire service (one line, 
one neutral, one ground). In the cable connecting to the power 
box, the earth terminal (Yellow Green) must be at least 30 mm 
longer than the phase and neutral conductors. If a stationary 
appliance la not 

fi

 tted with a supply cord and a plug, or with 

other means for disconnection from the supply mains having 
a contact separation in all poles that provide full disconnection 
under overvoltage category III conditions, the instructions shall 
state that means for disconnection must be incorporated in the 

fi

 xed wiring in accordance with the wiring rules.

The appliance should be supplied through a residual current 
device (RCD) with a rated tripping current not exceeding 30 mA.

WARNING: Removing or bypassing any GFCI breaker will 
result in an un safe spa and will void the spa’s warranty.
IMPORTANT: 

Should you ever 

fi

 nd the need to move or relocate 

your spa, it is essential
that you understand and apply these installation requirements. 
Your spa has been carefully engineered to provide maximum 
safety against electric shock. Remember, connecting the spa to 
an improperly wired circuit will negate many of its safety features. 

CONDUIT INSTALLATION INSTRUCTIONS

1. For the electrical connection, remove the panel that covers 

the installation systems compartment. 

2. Identify the junction box, loosen the screws and remove the 

cover.

3. Connect the power cable to the junction box and wire-up as 
shown in the wiring diagram and on the label applied to the inside 
of the control box cover.

 

AVOIDING THE RISK OF ELECTROCUTION
Risk of electrocution

•  The spa must be permanently connected to the electricity 

supply. The spa must be connected to a Ground Fault Circuit 
Interrupter (GFCI). Manufacturer does not supply a GFCI with 
the spa. Manufacturer recommends the GFCI be attached to 
the end of the spa’s electrical cord. The GFCI must be installed 
be a licensed, quali

fi

 ed electrical. GFCI devices must meet or 

exceed all national and local electrical codes.

Содержание MAWI SPA

Страница 1: ...anuale d installazione uso manutenzione Installation operation maintenance manual Installations Bedienungs Wartungsanleitung Manual de instalaci n uso mantenimiento Notice d installation utilisation m...

Страница 2: ...HNIS Techniche Daten Seite 5 Vorwort Seite 25 Anlagenbereich Seite 31 Anschlussplan Seite 32 Anschlussplan Seite 33 Plattenw rmetauscher installation Seite 33 Sandfilter installation Seite 34 Tafeln i...

Страница 3: ...ss1989 it ATENCI N PREPARACIONES PARA LA INSTALACI N V ase ficha t cnica del producto www glass1989 it ATTENTION PR PARATIFS DE MONTAGE Voire la fiche technique du produi www glass1989 it www glass198...

Страница 4: ...nelli Bathtub with panels Wanne mit paneelen Ba era con paneles Baignoire avec tabliers Vasca con pannelli Bathtub with panels Wanne mit paneelen Ba era con paneles Baignoire avec tabliers Vasca ad in...

Страница 5: ...ne all interno di armadi o scatole elettriche ATTENZIONE Segnala oggetti presenti solo in determinate versioni del prodotto OPTIONAL Segnala oggetti presenti solo se ordinati al momento dell acquisto...

Страница 6: ...e far scattare l interruttore automatico del quadro elettrico domestico Lasciate libero l accesso agli interruttori Lasciate libero l accesso al vano impianti per la periodica cura e manutenzione del...

Страница 7: ...me di protezione anti inquinamento consultare le autorit locali per maggiori informazioni sulle norme che regolano lo scarico di acqua trattata chimicamente Procedere con il collegamento C1 F1 sul mis...

Страница 8: ...on essere adeguatamente messo a terra e ci potrebbe causare scosse elettriche Una prolunga potrebbe inoltre causare un calo di tensione il quale a sua volta darebbe luogo ad un surriscaldamento del mo...

Страница 9: ...pletamente il guscio della Spa con un asciugamano pulito 3 Chiudere la copertura Se nella vostra zona cade molta neve o vi forte rischio gelate raccomandato coprire la copertura della Spa con un tetto...

Страница 10: ...iscaldatore 4 Pompa di ricircolo 5 Scambiatore di calore optional 6 Generatore di ozono optional 7 Scatola di controllo 8 Miscelatore collegamenti C1 F1 9 Scarico vasca O1 10 Pompa Whirlpool 11 Pompa...

Страница 11: ...ERIMETRALE PANNELLI OPTIONAL da collegare a un interruttore esterno a muro non fornito 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO On Off luce WALL SWIT...

Страница 12: ...IT 13 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 AUX M18 SCHEMA COLLEGAMENTI INSTALLAZIONE SCAMBIATORE DI CALORE OPTIONAL...

Страница 13: ...imentazione pompa A Tubo collegamento mandata B Tubo collegamento ritorno INSTALLAZIONE FILTRO A SABBIA OPTIONAL SCHEMA CONNESSIONI Collegare l alimentazione elettrica ai corrispondenti morsetti prese...

Страница 14: ...the power supply disconnected the electrical installer is able to operate in the presence of live parts inside cabinets or electrical boxes WARNING Inform features present only in some versions of the...

Страница 15: ...infestation is NOT covered under your warranty WARNING Manufacturer recommends that the spa be installed above ground Lowering the top of the spa to ground level or employing decking which raises stan...

Страница 16: ...circuit will negate many of the spa s safety features Improper wiring may also cause electrocution risk of fire and other risks of injuries Please read and follow the electrical installation requireme...

Страница 17: ...the steps listed below are completed Do not add chlorine if treating your spa with polyhexamethylene biguanide Biguanide PHMB sanitizer Before filling your spa for the first time check to ensure that...

Страница 18: ...ered with a spa cover Damage caused by either sun exposure or freezing is not covered under warranty Opening Instructions 5 Remove the spa cover Reinstall drain plug and hand tighten pump union Follow...

Страница 19: ...kimmer 2 Filter 3 Heater 4 Recirculation pump 5 Heat exchangers optional 6 Ozone generator optional 7 Control box 8 Mixer connections C1 F1 9 Bathtub drain O1 10 Whirlpool pump 11 Cascade pump only if...

Страница 20: ...ANEL PERIMETER LIGHT OPTIONAL to be connected to an external wall switch not supplied 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO On Off luce WALL SWITC...

Страница 21: ...EN 22 CONNECTIONS DIAGRAM AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 HEAT EXCHANGERS INSTALLATION OPTIONAL...

Страница 22: ...A Pipe connecting filter outlet to pump B Pipe connecting skimmer outlet to filter SAND FILTER INSTALLATION OPTIONAL WIRING DIAGRAM Connect if not already completed the electric mains of the building...

Страница 23: ...Wartungs und Reparaturarbeiten zust ndig Er muss in der Lage sein auch bei Anliegen von Spannung in Schaltschr nken oder Schaltk sten sofern diese nicht spannungslos gesetzt werden k nnen arbeiten zu...

Страница 24: ...schon einen Platz f r Ihren neuen Whirlpool ausgew hlt im Haus oder im Garten auf einer Terrasse oder auf einem Podest Stellen Sie die folgendenAspekte sicher Installieren Sie Ihren Whirlpool immer a...

Страница 25: ...ei auch an die Anweisungen in dieser Bedienungsanleitung Reinigen Sie den die Filter mindestens einmal im Monat Stellen Sie eine ordnungsgem e Zirkulation im gesamten Wassersystem des Whirlpools siche...

Страница 26: ...alter muss von einem zugelassenen Elektriker installiert werden Die FI Schutzschalter m ssen alle nationalen und regionalen elektrischen Normen und Vorschriften erf llen WARNUNG Um die Gefahr von Stro...

Страница 27: ...n Sie zum n chsten Schritt ber Zwei Mal die Taste WHIRLPOOL JETS dr cken Die D senpumpe l uft daraufhin insgesamt 20 Minuten damit das Wasser im Whirlpool zirkulieren kann berpr fen Sie nach dem Absch...

Страница 28: ...bereits bei niedrigeren Temperaturen ab Hohe Temperatur Alle Whirlpoolmodelle sind mit einer D senpumpe ausgestattet die die W rme vom Pumpenmotor an das Maschinenaggregat bertr gt Auf der Au enseite...

Страница 29: ...Filter 3 Durchlaufheizung 4 Umw lzpumpe 5 Plattenw rmetauscher optional 6 Ozongenerator optional 7 Systemschaltkasten 8 Mischer Anschl sse C1 F1 9 Auspu O1 10 Whirlpool Pumpe 11 Wasserf lle Pumpe nur...

Страница 30: ...RALE BELEEUCHTUNG DER TAFELN OPTION an einen u eren an der Wand montierten Schalter anzuschlie en nicht im Lieferumfang 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUT...

Страница 31: ...DE 32 ANSCHLUSSPLAN AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 PLATTENW RMETAUSCHER INSTALLATION OPTIONAL...

Страница 32: ...ng der Pumpe A Verbindungsschlauch Auslass B Verbindungsschlauch Einlass SANDFILTER INSTALLATION OPTIONAL SCHALTPLAN Falls noch nicht geschehen die Stromversorgung des Geb udes an die entsprechenden K...

Страница 33: ...erar en presencia de tensi n dentro de armarios o cajas el ctricas ATENCI N Indica objetos presentes s lo en algunas versiones del producto OPCIONAL Objetos presentes s lo si especificados en el pedid...

Страница 34: ...os en los componentes electr nicos o provocar que salte el disyuntor de circuitos de su hogar Deje un acceso libre al compartimiento del equipo para el cuidado y mantenimiento peri dico del spa ADVER...

Страница 35: ...ta CONEXIONES DEL COMPARTIMENTO T CNICO TODOS LOS TRABAJOS HIDR ULICOS DEBER N SER REALIZADOS POR UN INSTALADOR HIDR ULICO HABILITADO ATENCI N la conexi n de agua debe realizarse a la red de agua p bl...

Страница 36: ...tamente Contrate los servicios de un electricista autorizado Compruebe el los GFCI s antes de cada uso QU NO SE DEBE HACER Utilizar el spa sin la puerta del compartimiento del equipo Colocar aparatos...

Страница 37: ...ara ayudar a eliminar el agua residual de las tuber as de los surtidores de aire siga uno de los pasos que se indican a continuaci n 1 Retire la tapa del filtro el vertedero flotante la canastilla y e...

Страница 38: ...partimiento del equipo tenga una ventilaci n adecuada La entrada de aire del fondo no debe estar bloqueada Si la bomba de surtidores sigue apag ndose despu s de periodo de uso cortos consulte a un t c...

Страница 39: ...de flujo 4 Bomba de circulacion 5 Intercambiador de calor opcional 6 Generador de ozono opcional 7 Caja de control del sistema 8 Mezclador conexiones C1 F1 9 Descarga O1 10 Bomba de hidromasaje 11 Bom...

Страница 40: ...TIONAL LUZ PERIMETRAL DE LOS PANELES OPCIONAL se debe conectar a un interruptor externo de pared no suministrado 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A...

Страница 41: ...ES 42 ESQUEMA DE CONEXIONES AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 INSTALACI N INTERCAMBIADOR DE CALOR OPCIONAL...

Страница 42: ...de entrada del agua filtrada B Tubo para la conexi n de salida del agua que debe de ser filtrada INSTALACI N FILTRO ARENA OPCIONAL ESQUEMA DE CONEXI N Conecte si no lo ha hecho ya la alimentaci n el c...

Страница 43: ...s s il n est pas possible d op rer en l absence de tension il doit tre en mesure d op rer en pr sence de tension l int rieur es armoires ou des bo tiers lectriques ATTENTION Signale accessoires pr sen...

Страница 44: ...asse Il vous su t de v rifier les points suivants Installez toujours votre spa sur une surface plane dot e d une structure solide Un spa rempli d eau est tr s lourd Assurez vous que le site choisi est...

Страница 45: ...quilibrer le spa ATTENTION r gler les pieds centraux du Spa afin qu ils reposent correctement sur le sol Mawi Spa 175 200 STOP NOTE les cordons pour r gler les pieds ont t plac s pr s des pompes INST...

Страница 46: ...i s avec un cable la borne equipotentielle pr sente sur la SPA Aucun appareil lectrique de type lampe t l phone radio ou t l viseur ne sera install dans un rayon de 1 5 m du spa Le non respect de la d...

Страница 47: ...pour l hiver Si vous d sirez que votre spa reste vide sous des temp ratures inf rieures 0 C suivez les tapes des instructions de vidange du spa puis suivez les tapes suivantes REMARQUE ASSUREZ VOUS QU...

Страница 48: ...ompe s arr te suite un exc s de chaleur assurez vous que le bloc technique est bien a r Le trou d air dans le bas du syst me ne doit pas tre obstru Si votre pompe jet continue s arr ter apr s de court...

Страница 49: ...e 3 R chau eur 4 Pompe de circulation 5 Echangeur de chaleur optionnel 6 G n rateur d ozone optionnel 7 Bo te de contr le 8 M langeur connexions C1 F1 9 D charge O1 10 Pompe tourbillon 11 Pompe Cascad...

Страница 50: ...OTH OPTIONAL LUMI RE P RIM TRIQUE DES PANNEAUX EN OPTION raccorder un interrupteur externe au mur non fourni 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO...

Страница 51: ...FR 52 SCH MA DES RACCORDEMENTS AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 INSTALLATION CHANGEUR DE CHALEUR OPTIONAL...

Страница 52: ...ement refoulement filtre pompe B Tuyau de raccordement refoulement skimmer filtre INSTALLATION FILTRE SABLE OPTIONAL DIAGRAMME DE C BLAGE Si cela n a pas encore t fait raccorder l alimentation lectriq...

Страница 53: ...54 Spa Spa Spa...

Страница 54: ...RU 55 A 12 spa...

Страница 55: ...RU 56 314 2 pH 1 0 Spa Mawi Spa 175 200 STOP C1 F1 O1 C V...

Страница 56: ...RU 57 220 230 16 3 30 III 4000 30 1 2 3 30 1 5 1 5 6 2 10 AWG 1 5 1 5 38 C 40 C PHMB Soft Soak...

Страница 57: ...RU 58 35 C 125 ppm 150 ppm pH 7 4 7 6 10 1 950 2 WHIRLPOOL JETS 20 38 40 C 24 32 C 2 WHIRLPOOL JETS 20 3 5 ppm 3 ppm 1 950 2 WHIRLPOOL JETS 20 TA 125 ppm CH 150 ppm pH 7 4 7 6 3 5 ppm 10 15 1 2 3 4 5...

Страница 58: ...RU 59 Jets Spa...

Страница 59: ...RU 60 1 2 3 4 5 6 7 8 C1 F1 9 1 10 11...

Страница 60: ...RU 61 C V BLUETOOTH OPTIONAL 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO On Off luce WALL SWITCH On Off light Min 1 Max 2...

Страница 61: ...RU 62 AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2...

Страница 62: ...RU 63 L N L J30 CP N C A B...

Страница 63: ...4 paneles Installation au centre de la pi ce avec 4 panneaux 4 Installazione ad angolo con 2 pannelli Corner installation with 2 panels Eckinstallation mit 2 Paneelen Instalaci n angular con 2 paneles...

Страница 64: ...PANNELLI PANELS I T D G M V W A E L...

Страница 65: ...i pannelli sotto al bordo vasca Detail of the panels under the edge of the tub Details der Tafeln unter dem Wannenrand Detalle de los paneles debajo del borde de la ba era D tail des panneaux sous le...

Страница 66: ...Glass 1989 s r l Via Baite 12 E Zona Industriale 31046 Oderzo TV Italy Tel 39 0422 7146 r a www glass1989 it...

Страница 67: ...R 11_2019...

Отзывы: