background image

EN

16

Do not remove the sticker from the product!

Figure

 

A

WARNING.

• 

Read the manual carefully in all its parts before using the 
product.

•  Keep this manual for further consultation.
•  The manual is intended for di

 erent models and versions, so 

the product may look di

 erent from the manual illustrations. 

However the instructions remain unchanged.

•  The company reserves the right to make any changes 

considered suitable without notice or replacement.

•  This product is intended only for the use for which it has been 

designed. The manufacturer is not responsible for any damage 
caused by improper useage.

•  The product identification data (model, power, voltage, 

manufacturer’s name) are contained in the silver data plate 
on the unit and on the warranty card. It is issued at the time 
of testing.

•  Make sure that the drain is always e

  cient.

•  Ensure that the 

fl

 oor around the product is always dry and 

clean, to avoid slips or falls entering or editing the product 
itself.

•  Use and installation of a cover
•  Appliance must be permanently connected to 

fi

 xed wiring.

•  Parts containing live parts, except parts supplied with safety 

extra-low voltage not exceeding 12 V, must be inaccessible 
to a person in the bath.

•  When the product is not used, disconnect it completely by 

turning o

  the double-pole switch installed on upstream the 

appliance.

•  Precaution to avoid damage when the appliance is left empty 

for an extended period.

All measurements are in mm.

PRE-INSTALLATION REQUIREMENTS

IMPORTANT: given the high capacity and weight of the 
spa (see product speci

fi

 cations), a speci

fi

 c structural and 

building services engineering study is necessary.

SITE PREPARATION

You probably have a spot picked out for your new spa, whether 
it’s indoors or outdoors, on a patio or on a deck. Just make sure 
you check the following:
•Always put your spa on a structurally sound, level surface. A 

fi

 lled 

spa is very heavy. Make certain that the location you choose can 
support the weight of your 

fi

 lled spa.

•Don’t forget to level your spa before 

fi

 lling it. (See the Spa 

Leveling Preparation section of this manual.) 
•Locate your equipment compartment, which houses all of the 

electrical components, in a place where water will drain away 
from it. Allowing water into the equipment compartment can 
damage the electronics, or may result in tripping your house’s 
circuit breaker.
•Leave access to the equipment compartment for periodic spa 
care and maintenance.

 WARNING: Damage to the spa’s equipment compartment 
components or internal plumbing as a result of rodent 
infestation is NOT covered under your warranty! 

WARNING
Manufacturer recommends that the spa be installed above 
ground. Lowering the top of the spa to ground level, or 
employing decking which raises standing level toward 
the top of the spa substantially increases the hazard of 
accidental entry. Consult a licensed building contractor to 
design or evaluate your custom decking requirements. 

DECK INSTALLATION

To be certain your deck can support your spa, you must know 
the deck’s maximum load capacity. Consult a quali

fi

 ed building 

contractor or structural engineer. To 

fi

 nd the weight of your spa, 

its contents and occupants, refer to the Spa Speci

fi

 cation chart 

on back page. This weight per square foot must not exceed the 
structure’s rated capacity, or serious structural damage could 
result.

INDOOR/BASEMENT INSTALLATION

Be aware of some special requirements if you place your spa 
indoors. Water will accumulate around the spa, so 

fl

 ooring 

materials must provide a good grip when wet. Proper drainage 
is essential to prevent a build-up of water around the spa. When 
building a new room for the spa it is recommended that a 

fl

 oor 

drain be installed. The humidity will naturally increase with the 
spa indoors. Water may get into ironwork and produce oxide, 
mildew, or other problems. Check for airborne moisture’s e

 ects 

on exposed wood, paper, etc. in the room. To minimize these 
e

 ects, it is best to provide plenty of ventilation to the spa area. 

An architect can help to determine if more ventilation must be 
installed. 

WARNING: Please keep the area around your spa well 
ventilated when it is installed indoors or in a con

fi

 ned area.

To prevent the formation of condensation inside the space 
around the bathtub, make a ventilation system having a 
minimum area of 314cm

2

. This system must be made in such a 

way as to prevent water in

fi

 ltration.

Inadequate ventilation around the spa could cause a build-up 
of a higher-than-normal concentration of spa chemicals and/
or bacterial fragments. These dispersed spa chemicals and/or 
bacterial fragments can be inhaled, and may result in breathing 
di

  culties or lung damage in certain people su

 ering from a 

compromised immune system or respiratory infection. If you or 
other bathers are a

 ected by this condition, please seek medical 

attention as soon as possible.

In addition to the above, properly clean and maintain your spa 
as follows:
•Follow all procedures in this owner’s manual and printed 
instructions on all water care (chemical) products packaging.
•Test the water regularly to ensure proper levels of sanitizers, 
pH, and other water care requirements.
•Drain, clean, and re

fi

 ll your spa with fresh water on a regular 

schedule, and in accordance with this owner’s manual.

Содержание MAWI SPA

Страница 1: ...anuale d installazione uso manutenzione Installation operation maintenance manual Installations Bedienungs Wartungsanleitung Manual de instalaci n uso mantenimiento Notice d installation utilisation m...

Страница 2: ...HNIS Techniche Daten Seite 5 Vorwort Seite 25 Anlagenbereich Seite 31 Anschlussplan Seite 32 Anschlussplan Seite 33 Plattenw rmetauscher installation Seite 33 Sandfilter installation Seite 34 Tafeln i...

Страница 3: ...ss1989 it ATENCI N PREPARACIONES PARA LA INSTALACI N V ase ficha t cnica del producto www glass1989 it ATTENTION PR PARATIFS DE MONTAGE Voire la fiche technique du produi www glass1989 it www glass198...

Страница 4: ...nelli Bathtub with panels Wanne mit paneelen Ba era con paneles Baignoire avec tabliers Vasca con pannelli Bathtub with panels Wanne mit paneelen Ba era con paneles Baignoire avec tabliers Vasca ad in...

Страница 5: ...ne all interno di armadi o scatole elettriche ATTENZIONE Segnala oggetti presenti solo in determinate versioni del prodotto OPTIONAL Segnala oggetti presenti solo se ordinati al momento dell acquisto...

Страница 6: ...e far scattare l interruttore automatico del quadro elettrico domestico Lasciate libero l accesso agli interruttori Lasciate libero l accesso al vano impianti per la periodica cura e manutenzione del...

Страница 7: ...me di protezione anti inquinamento consultare le autorit locali per maggiori informazioni sulle norme che regolano lo scarico di acqua trattata chimicamente Procedere con il collegamento C1 F1 sul mis...

Страница 8: ...on essere adeguatamente messo a terra e ci potrebbe causare scosse elettriche Una prolunga potrebbe inoltre causare un calo di tensione il quale a sua volta darebbe luogo ad un surriscaldamento del mo...

Страница 9: ...pletamente il guscio della Spa con un asciugamano pulito 3 Chiudere la copertura Se nella vostra zona cade molta neve o vi forte rischio gelate raccomandato coprire la copertura della Spa con un tetto...

Страница 10: ...iscaldatore 4 Pompa di ricircolo 5 Scambiatore di calore optional 6 Generatore di ozono optional 7 Scatola di controllo 8 Miscelatore collegamenti C1 F1 9 Scarico vasca O1 10 Pompa Whirlpool 11 Pompa...

Страница 11: ...ERIMETRALE PANNELLI OPTIONAL da collegare a un interruttore esterno a muro non fornito 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO On Off luce WALL SWIT...

Страница 12: ...IT 13 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 AUX M18 SCHEMA COLLEGAMENTI INSTALLAZIONE SCAMBIATORE DI CALORE OPTIONAL...

Страница 13: ...imentazione pompa A Tubo collegamento mandata B Tubo collegamento ritorno INSTALLAZIONE FILTRO A SABBIA OPTIONAL SCHEMA CONNESSIONI Collegare l alimentazione elettrica ai corrispondenti morsetti prese...

Страница 14: ...the power supply disconnected the electrical installer is able to operate in the presence of live parts inside cabinets or electrical boxes WARNING Inform features present only in some versions of the...

Страница 15: ...infestation is NOT covered under your warranty WARNING Manufacturer recommends that the spa be installed above ground Lowering the top of the spa to ground level or employing decking which raises stan...

Страница 16: ...circuit will negate many of the spa s safety features Improper wiring may also cause electrocution risk of fire and other risks of injuries Please read and follow the electrical installation requireme...

Страница 17: ...the steps listed below are completed Do not add chlorine if treating your spa with polyhexamethylene biguanide Biguanide PHMB sanitizer Before filling your spa for the first time check to ensure that...

Страница 18: ...ered with a spa cover Damage caused by either sun exposure or freezing is not covered under warranty Opening Instructions 5 Remove the spa cover Reinstall drain plug and hand tighten pump union Follow...

Страница 19: ...kimmer 2 Filter 3 Heater 4 Recirculation pump 5 Heat exchangers optional 6 Ozone generator optional 7 Control box 8 Mixer connections C1 F1 9 Bathtub drain O1 10 Whirlpool pump 11 Cascade pump only if...

Страница 20: ...ANEL PERIMETER LIGHT OPTIONAL to be connected to an external wall switch not supplied 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO On Off luce WALL SWITC...

Страница 21: ...EN 22 CONNECTIONS DIAGRAM AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 HEAT EXCHANGERS INSTALLATION OPTIONAL...

Страница 22: ...A Pipe connecting filter outlet to pump B Pipe connecting skimmer outlet to filter SAND FILTER INSTALLATION OPTIONAL WIRING DIAGRAM Connect if not already completed the electric mains of the building...

Страница 23: ...Wartungs und Reparaturarbeiten zust ndig Er muss in der Lage sein auch bei Anliegen von Spannung in Schaltschr nken oder Schaltk sten sofern diese nicht spannungslos gesetzt werden k nnen arbeiten zu...

Страница 24: ...schon einen Platz f r Ihren neuen Whirlpool ausgew hlt im Haus oder im Garten auf einer Terrasse oder auf einem Podest Stellen Sie die folgendenAspekte sicher Installieren Sie Ihren Whirlpool immer a...

Страница 25: ...ei auch an die Anweisungen in dieser Bedienungsanleitung Reinigen Sie den die Filter mindestens einmal im Monat Stellen Sie eine ordnungsgem e Zirkulation im gesamten Wassersystem des Whirlpools siche...

Страница 26: ...alter muss von einem zugelassenen Elektriker installiert werden Die FI Schutzschalter m ssen alle nationalen und regionalen elektrischen Normen und Vorschriften erf llen WARNUNG Um die Gefahr von Stro...

Страница 27: ...n Sie zum n chsten Schritt ber Zwei Mal die Taste WHIRLPOOL JETS dr cken Die D senpumpe l uft daraufhin insgesamt 20 Minuten damit das Wasser im Whirlpool zirkulieren kann berpr fen Sie nach dem Absch...

Страница 28: ...bereits bei niedrigeren Temperaturen ab Hohe Temperatur Alle Whirlpoolmodelle sind mit einer D senpumpe ausgestattet die die W rme vom Pumpenmotor an das Maschinenaggregat bertr gt Auf der Au enseite...

Страница 29: ...Filter 3 Durchlaufheizung 4 Umw lzpumpe 5 Plattenw rmetauscher optional 6 Ozongenerator optional 7 Systemschaltkasten 8 Mischer Anschl sse C1 F1 9 Auspu O1 10 Whirlpool Pumpe 11 Wasserf lle Pumpe nur...

Страница 30: ...RALE BELEEUCHTUNG DER TAFELN OPTION an einen u eren an der Wand montierten Schalter anzuschlie en nicht im Lieferumfang 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUT...

Страница 31: ...DE 32 ANSCHLUSSPLAN AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 PLATTENW RMETAUSCHER INSTALLATION OPTIONAL...

Страница 32: ...ng der Pumpe A Verbindungsschlauch Auslass B Verbindungsschlauch Einlass SANDFILTER INSTALLATION OPTIONAL SCHALTPLAN Falls noch nicht geschehen die Stromversorgung des Geb udes an die entsprechenden K...

Страница 33: ...erar en presencia de tensi n dentro de armarios o cajas el ctricas ATENCI N Indica objetos presentes s lo en algunas versiones del producto OPCIONAL Objetos presentes s lo si especificados en el pedid...

Страница 34: ...os en los componentes electr nicos o provocar que salte el disyuntor de circuitos de su hogar Deje un acceso libre al compartimiento del equipo para el cuidado y mantenimiento peri dico del spa ADVER...

Страница 35: ...ta CONEXIONES DEL COMPARTIMENTO T CNICO TODOS LOS TRABAJOS HIDR ULICOS DEBER N SER REALIZADOS POR UN INSTALADOR HIDR ULICO HABILITADO ATENCI N la conexi n de agua debe realizarse a la red de agua p bl...

Страница 36: ...tamente Contrate los servicios de un electricista autorizado Compruebe el los GFCI s antes de cada uso QU NO SE DEBE HACER Utilizar el spa sin la puerta del compartimiento del equipo Colocar aparatos...

Страница 37: ...ara ayudar a eliminar el agua residual de las tuber as de los surtidores de aire siga uno de los pasos que se indican a continuaci n 1 Retire la tapa del filtro el vertedero flotante la canastilla y e...

Страница 38: ...partimiento del equipo tenga una ventilaci n adecuada La entrada de aire del fondo no debe estar bloqueada Si la bomba de surtidores sigue apag ndose despu s de periodo de uso cortos consulte a un t c...

Страница 39: ...de flujo 4 Bomba de circulacion 5 Intercambiador de calor opcional 6 Generador de ozono opcional 7 Caja de control del sistema 8 Mezclador conexiones C1 F1 9 Descarga O1 10 Bomba de hidromasaje 11 Bom...

Страница 40: ...TIONAL LUZ PERIMETRAL DE LOS PANELES OPCIONAL se debe conectar a un interruptor externo de pared no suministrado 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A...

Страница 41: ...ES 42 ESQUEMA DE CONEXIONES AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 INSTALACI N INTERCAMBIADOR DE CALOR OPCIONAL...

Страница 42: ...de entrada del agua filtrada B Tubo para la conexi n de salida del agua que debe de ser filtrada INSTALACI N FILTRO ARENA OPCIONAL ESQUEMA DE CONEXI N Conecte si no lo ha hecho ya la alimentaci n el c...

Страница 43: ...s s il n est pas possible d op rer en l absence de tension il doit tre en mesure d op rer en pr sence de tension l int rieur es armoires ou des bo tiers lectriques ATTENTION Signale accessoires pr sen...

Страница 44: ...asse Il vous su t de v rifier les points suivants Installez toujours votre spa sur une surface plane dot e d une structure solide Un spa rempli d eau est tr s lourd Assurez vous que le site choisi est...

Страница 45: ...quilibrer le spa ATTENTION r gler les pieds centraux du Spa afin qu ils reposent correctement sur le sol Mawi Spa 175 200 STOP NOTE les cordons pour r gler les pieds ont t plac s pr s des pompes INST...

Страница 46: ...i s avec un cable la borne equipotentielle pr sente sur la SPA Aucun appareil lectrique de type lampe t l phone radio ou t l viseur ne sera install dans un rayon de 1 5 m du spa Le non respect de la d...

Страница 47: ...pour l hiver Si vous d sirez que votre spa reste vide sous des temp ratures inf rieures 0 C suivez les tapes des instructions de vidange du spa puis suivez les tapes suivantes REMARQUE ASSUREZ VOUS QU...

Страница 48: ...ompe s arr te suite un exc s de chaleur assurez vous que le bloc technique est bien a r Le trou d air dans le bas du syst me ne doit pas tre obstru Si votre pompe jet continue s arr ter apr s de court...

Страница 49: ...e 3 R chau eur 4 Pompe de circulation 5 Echangeur de chaleur optionnel 6 G n rateur d ozone optionnel 7 Bo te de contr le 8 M langeur connexions C1 F1 9 D charge O1 10 Pompe tourbillon 11 Pompe Cascad...

Страница 50: ...OTH OPTIONAL LUMI RE P RIM TRIQUE DES PANNEAUX EN OPTION raccorder un interrupteur externe au mur non fourni 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO...

Страница 51: ...FR 52 SCH MA DES RACCORDEMENTS AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2 INSTALLATION CHANGEUR DE CHALEUR OPTIONAL...

Страница 52: ...ement refoulement filtre pompe B Tuyau de raccordement refoulement skimmer filtre INSTALLATION FILTRE SABLE OPTIONAL DIAGRAMME DE C BLAGE Si cela n a pas encore t fait raccorder l alimentation lectriq...

Страница 53: ...54 Spa Spa Spa...

Страница 54: ...RU 55 A 12 spa...

Страница 55: ...RU 56 314 2 pH 1 0 Spa Mawi Spa 175 200 STOP C1 F1 O1 C V...

Страница 56: ...RU 57 220 230 16 3 30 III 4000 30 1 2 3 30 1 5 1 5 6 2 10 AWG 1 5 1 5 38 C 40 C PHMB Soft Soak...

Страница 57: ...RU 58 35 C 125 ppm 150 ppm pH 7 4 7 6 10 1 950 2 WHIRLPOOL JETS 20 38 40 C 24 32 C 2 WHIRLPOOL JETS 20 3 5 ppm 3 ppm 1 950 2 WHIRLPOOL JETS 20 TA 125 ppm CH 150 ppm pH 7 4 7 6 3 5 ppm 10 15 1 2 3 4 5...

Страница 58: ...RU 59 Jets Spa...

Страница 59: ...RU 60 1 2 3 4 5 6 7 8 C1 F1 9 1 10 11...

Страница 60: ...RU 61 C V BLUETOOTH OPTIONAL 230 V GROUND NEUTRAL LINE L1 LINEA L2 L3 N INPUT 100 240V 2 2A 287387 9 INTERRUTTORE A MURO On Off luce WALL SWITCH On Off light Min 1 Max 2...

Страница 61: ...RU 62 AUX M18 Entrate acqua fredda Cold water inlet Entrate acqua calda Hot water inlet 1 2 1 2...

Страница 62: ...RU 63 L N L J30 CP N C A B...

Страница 63: ...4 paneles Installation au centre de la pi ce avec 4 panneaux 4 Installazione ad angolo con 2 pannelli Corner installation with 2 panels Eckinstallation mit 2 Paneelen Instalaci n angular con 2 paneles...

Страница 64: ...PANNELLI PANELS I T D G M V W A E L...

Страница 65: ...i pannelli sotto al bordo vasca Detail of the panels under the edge of the tub Details der Tafeln unter dem Wannenrand Detalle de los paneles debajo del borde de la ba era D tail des panneaux sous le...

Страница 66: ...Glass 1989 s r l Via Baite 12 E Zona Industriale 31046 Oderzo TV Italy Tel 39 0422 7146 r a www glass1989 it...

Страница 67: ...R 11_2019...

Отзывы: