22/06/2010   MT04_A30_B_VI110L_GIVI_ENG   REV.B 

 

 

9

32

 

 

 

  STORING OF PROGRAMMES AND DATA

 

 

The programming of counter 

VISION 110

 

is carried out by the Manufacturer who 

knows the access codes and the procedures (configuration). The operator can 

carry out all operations. All the information is stored permanently and can be only 

modified by reforming it all from the beginning. 

Furthermore, the instrument can permanently memorise the latest operations 

which are considered as last data entered. 

 

So the following information is maintained 

A) 

measurement unit selected (MM/INCH/DEG). 

B) 

function settings entered. 

C) 

last Axis counting position and eventual messages (not 

transitory) concerning abnormal situations, e.g. overflow 

message. 

 

IMPORTANT NOTE: 

When there is a power failure, the instrument cannot register any scale 

movement (through inertia, manual movements, thermal expansion) whether in 

ABS or INC. If this happens, the data on the display is not reliable because it 

cannot indicate new positions but only those previous to the power failure. 

 

 

  

 

   

SETTING CONFIGURATION 

 

For the configuration of the device some  internal parameters have to be used. 

To recall the configuration, push the button P, enter the password number and 

confirm by button SET.  The selection of parameter is made by repeatedly 

pressing button P. 

 

Important notes :  

1) To access parameters section,  it is necessary to enter a 6-digit 

password  (manufacturer   code: “000000”).  It is possible to change this  

code.  

2) During the parameter setting, the display will show “P”. 

 
Parameters currently entered are the following: 

Parameter 01

 – CHOICE OF AXIS RESOLUTION 

Parameter 02

 – INVERSION OF COUNTING MODE 

Parameter 03

 – LINEAR CORRECTION 

Parameter 04

 – ENABLE AND SET THE REF VALUE OF INCREMENTAL  

                           QUOTA 

Parameter 05

 – ENABLE AND SET THE REF VALUE OF ABSOLUTE  

                           QUOTA 

Parameter 06

 – ENABLE AND SET TIME FOR DEVICE SELF-SWITCH.  

                           OFF  

Parameter 07

 – ENABLE RESET/PRESET INCREMENTAL QUOTA  

Parameter 08

 - ENABLE RESET/PRESET ABSOLUTE QUOTA 

Parameter 09

 – ENABLE AND SET TIME FOR STAND-BY OF DISPLAY 

Parameter 10

 – SET FACTOR OF FREE CALCULATION 

Parameter 80

 – MODIFY PASSWORD TO ENTER PARAMETERS 

Parameter 89

 – DEVICE DIAGNOSTIC

 

Parameter 90

 – RESERVED 

Содержание VISION 110L

Страница 1: ...9 0362 366876 www givimisure it sales givimisure it GIVI MISURE S R L A SOCIO UNICO C F e Iscrizione al Reg Imprese di Monza e Brianza n 04355540156 Cap Soc 51 480 00 I V OPERATION MANUAL DIGITAL READ...

Страница 2: ...e made We must ask you to read through these pages carefully in order to ensure proper operation of your new system This device is controlled by a powerful microcomputer and is programmable via the ke...

Страница 3: ...nsulation characteristics conforming to the current regulations The installation of the instrument must be carried out by authorised skilled staff who will follow the regulations stated by the Manufac...

Страница 4: ...REMOVED Y Drilling template 92x66 mm BATTERY INSERTION Open the door of battery case and insert two batteries Alkaline size AA 1 5V taking care about the polarity see the drawing Close the door befor...

Страница 5: ...e fixed on any kind of non magnetic surface For band MP200 only For a better protection of magnetic band from shavings liquid sprinklings powder etc we suggest to always use the metal sheet cover CV10...

Страница 6: ...ccurate cleaning of the surface Use the remaining part of cover tape for mechanical fixing and earth connection of the structure by means of socket head screws M3x8 RESISTANCE TO CHEMICAL AGENTS LOW I...

Страница 7: ...side marked by arrows toward the surface of magnetic strip Once mounting is carried place cables and move manually the sensor for the total run in order to be sure it can freely slide without any obs...

Страница 8: ...setting made see manual and indicates the function has been activated or ready to be carried out If it is blinking scale measuring is taking place fixed light or no light at all indicates the function...

Страница 9: ...sitions but only those previous to the power failure SETTING CONFIGURATION For the configuration of the device some internal parameters have to be used To recall the configuration push the button P en...

Страница 10: ...press more until the desired parameter will be shown e g P 0 2 press To confirm the selection and enter its setting d i r Set the parameter configuration following the instructions hereafter describe...

Страница 11: ...1 press more Until the desired resolution e g 0 1 in mm r 0 1 press To confirm the value and return to the parameters P 0 1 press To quit the configuration 1 2 3 4 5 CHOICE OF AXIS RESOLUTION IN ANGUL...

Страница 12: ...n r A n g press First position of number will blink XXXXX press To select the second position 0 XXXX press To set the value 0 9 0 XXXX push and To set the other values 0 2 8 6 4 press To confirm the v...

Страница 13: ...ng press To enter the configuration and select the parameter P 0 2 press To confirm the selection and enter its setting d i r press The display will show d i r press To confirm the value and return to...

Страница 14: ...ositive or negative For example the measured piece can be longer or shorter A mm 400 20 longer piece has an error of 200 m B mm 399 88 shorter piece has an error of 120 m In case A we will have 400 20...

Страница 15: ...on the starting point of the movement e g 0 mm press To input the first quota Display will show for one second S t o r E Place the reader head on the final point of the movement e g 400 mm press To i...

Страница 16: ...s in incremental counting mode Example of setting value of REF 10 00 mm press To enter the configuration and select the parameter P 0 4 press Display will show yes no to indicate the set mode n o pres...

Страница 17: ...is in absolute counting mode Example of setting value of REF 5 00 mm press To enter the configuration and select the parameter P 0 5 press Display will show yes no to indicate the set mode n o press T...

Страница 18: ...cate the set mode n o press To enable the automatic switching off y e s press The first digit will blink XXX XX select and To set the time 0 0 1 8 0 press To confirm the value and return to parameter...

Страница 19: ...C STAND BY It is possible to enable and program a waiting time for an automatic stand by of the device Time is displayed in seconds and maximum programmable time is 12 hours During the stand by time t...

Страница 20: ...through the following formula QUOTA TO BE DISPLAYED FCL QUOTA DISPLAYED Let us suppose we have to carry out an operation moving the axis for 400 mm but in the meantime we have to make a diagonal cut o...

Страница 21: ...play will show F C L 0 select and To set the digits 01 F C L 0 1 press To confirm the value and return to the parameters selection P 1 0 press To quit the configuration 1 2 3 4 5 Now the FCL 0 87500 i...

Страница 22: ...he configuration Example of setting press To enter the configuration and select the parameter P 8 0 press The display will show 0 0 0 0 0 use and To enter the password XXXXX press When setting is comp...

Страница 23: ...ng on segment by segment _ press To display again all the available segments or 1 8 8 8 8 8 8 press To confirm the value and return to the parameters P 8 9 press To quit the configuration 1 2 3 4 SELF...

Страница 24: ...ABS INC All the information concerning movement of the Axis is simultaneously updated on both counters Information entered by the operator however only affects the counting system counter previously c...

Страница 25: ...3 on the axis press the first digit will blink XXX XX press to select the second digit 0 XX XX press and input a value 0 9 0 XX XX select and to set the other digits 0 1 1 3 0 press and the value is p...

Страница 26: ...d enabled through parameters P04 in case of INC or counting mode or P05 if in ABS counting mode Apart from the selected counting mode it is possible to recall the corresponding REF quota through examp...

Страница 27: ...01 0 1 2 3 decimal points setting mode PROTECTION DEGREE IP 43 according to standard DIN 40050 TEMPERATURE WORKING 0 50 C STORAGE 20 70 C HUMIDITY 95 not condensed WEIGHT 100 g MAGNETIC SENSOR mod VI1...

Страница 28: ...IF Without limitation the Manufacturer is released from all claims against special indirect or consequential damages including but not limited to lost profits or other damages due to loss of productio...

Страница 29: ...22 06 2010 MT04_A30_B_VI110L_GIVI_ENG REV B 29 32 SPECIAL FUNCTIONS ON CUSTOMER S REQUEST...

Страница 30: ...22 06 2010 MT04_A30_B_VI110L_GIVI_ENG REV B 30 32...

Страница 31: ...22 06 2010 MT04_A30_B_VI110L_GIVI_ENG REV B 31 32...

Страница 32: ...22 06 2010 MT04_A30_B_VI110L_GIVI_ENG REV B 32 32...

Отзывы: