22/06/2010 MT04_A30_B_VI110L_GIVI_ENG REV.B
25
32
RESETTING/PRESETTING OF A DATUM
To make this operation enabled, set the corresponding parameter 07
(Incremental mode) or parameter 08 (Absolute mode).
Quite apart from the counting system selected, ABS or INC mode, zero
resetting of a quota (reset) is obtained as follows:
example :
1 2 3 . 4 5
press
and datum is reset
0 . 0 0
To enter a value (preset), for example 113.03 on the axis:
press
the first digit will blink
XXX.XX
press
to select the second digit
0
XX.XX
press
and input a value (0-9)
0
XX.XX
select
and
to set the other digits
0 1 1 3 .0
press
and the value is preset
1 1 3 . 0 3
The max. presettable value cannot be larger than the counting capacity of the
instrument (6 ½ digits and one decimal point) e.g.:
from
-199999 9
to
1999999
for resolution in millimetres
from
-199999.9
to
199999.9
for decimal resolution
from
-19999.99
to
19999.99
for centesimal resolution
NOTE:
TO ENTER A VALUE ON A DEVICE, SET IN INCHES (1/16–1/3 – 1/64)
SUCH VALUE MUST BE ENTERED IN INCHES DECIMALS.