22/06/2010 MT04_A30_B_VI110L_GIVI_ENG REV.B
12
32
Example for setting a resolution 0.1° in angular mode :
press
To enter the configuration and
select the parameter
P 0 1
press
To confirm the selection and
enter its setting
r 0 . 0 1
press
more
Up to Angular resolution
r A n g
press
First position of number will
blink
.XXXXX
press
To select the second position
0.
XXXX
press
To set the value (0-9)
0.
XXXX
push
and
To set the other values
0 . 2 8 6 4
press
To confirm the value and go
into the selection of decimals.
r 0 . 0 1
press
more
Up to the desired resolution
(e.g.: 0.1 in degrees)
r 0 . 1
press
To confirm the value and return
to the parameters
P 0 1
press
To quit the configuration.
1 2 3 . 4
Parameter 02 - INVERSION OF COUNTING DIRECTION