background image

Figure 2

(7) IR PIR 2 remote control (end customer), included in the scope of delivery
(8) IR PIR 1 remote control (installation engineer), see Accessories

3 Function

Intended use

-

Automatic switching of lighting depending on the heat motion and ambient brightness.

-

Indoor ceiling mounting, surface-mounted

Product characteristics

-

2-point light control

-

Functions settable with IR remote controls

-

Restriction of the detection field by switching off individual sensors or push-on cover.

-

Operation with IR remote control, 2-wire extension or installation button

-

Teach function for adjustment of the brightness threshold, in combination with IR remote
controls

-

Switch-off warning

-

Short-time operation, e.g. to activate acoustic signal encoders

-

Display LEDs

-

Presence simulation

-

Function as twilight switch

-

Dynamic run-on time

-

Extension of the detection area through parallel switching of multiple devices

i

The extension of the detection area with 3-wire extensions is not possible.

Automatic operation

The device detects heat motions of people, animals and objects.
-

The light is switched on if a person enters the detection area and the brightness is below
the set threshold.
The run-on time restarts with each detected motion.

-

The light is switched off when it is no longer required because: 
No more movement is detected in the detection area and the run-on time has elapsed or
the ambient light is too bright.
The switch-off brightness is calculated from the set brightness threshold and the connected
light.
To avoid brief shading from causing switch-off, switch-off only takes place when the set
run-on time has elapsed. The run-on time does not restart on movement detection for as
long as the switch-off brightness is exceeded.

i

The minimum switch-off brightness is 100 lux, even if a lower value is set.

82593212

12.01.2017

2/18

Presence detector and motion detector 360° compact

Содержание 2399 02

Страница 1: ...count which support dangerous voltages to the device and or load Do not press on the sensor window Device can be damaged Keep button cells out of reach of children If button cells are swallowed get me...

Страница 2: ...ion area through parallel switching of multiple devices i The extension of the detection area with 3 wire extensions is not possible Automatic operation The device detects heat motions of people anima...

Страница 3: ...ted motions prolong the run on time or the light is switched on depending on brightness Times are not saved Function as twilight switch The function is active as soon as all the PIR sensors have been...

Страница 4: ...s the brightness threshold Set 2 Pressing for longer than 10 seconds Activating the settings saved by the installation engineer Pressing for longer than 10 seconds Switching the presence simulation on...

Страница 5: ...ire extension or installation button o Press the button for shorter than 0 4 seconds Light is switched on continuously The blue LED lights up i Automatic operation is switched on again using the butto...

Страница 6: ...longer required o Press the Set 2 button for longer than 10 seconds Settings saved by the installation engineer are active again Switching the presence simulation on or off o Press the button for lon...

Страница 7: ...ement on the ground 2 Range for radial movement on the ground 3 Range for typical movements at desks e g torso movement 4 Range of fine detection at desks e g mouse movements When used as a presence d...

Страница 8: ...Aligning the device The device has three independent PIR sensors for motion detection Figure 5 Figure 5 Detection field areas A B and C installation height 2 50 m Figure 6 Arrangement of the areas A B...

Страница 9: ...ins 10 Screws o Pull off the decor ring 5 Figure 7 o Loosen the screws 10 Figure 7 Installing the connection box Figure 8 Connection box 11 Fastening holes 12 Cable entry surface mounted 13 Thin point...

Страница 10: ...appliance box The screws are not included in the scope of delivery Connecting the device Figure 9 Connection diagram single device Figure 10 Connection diagram parallel circuit for expanding the detec...

Страница 11: ...only necessary if manual operation is also desired i Lit installation buttons may only be connected if they have an N terminal i In the case of single devices a 2 wire extension can be used as an alte...

Страница 12: ...30 s 2 min 5 min 30 min Set run on time Pressing for longer than 10 seconds Saving ambient brightness as brightness threshold Setting the brightness threshold 0 1 h Setting individual run on time Dyn...

Страница 13: ...there is no distinct demarcation of the blocked out detection area If all the PIR sensors have been switched off then the device works as a twilight switch o Press the PIR A PIR B or PIR C button for...

Страница 14: ...ff once To cancel a running run on time set the special function Continuous on for example and then switch back to Automatic operation see Operation Setting the dynamic run on time The device adapts t...

Страница 15: ...function press the Reset button for between 4 and 10 seconds Saving settings Save the settings so that if necessary the end customer can recall them using the Set 2 button No values are saved in the a...

Страница 16: ...AC 230 V and 35 C Incandescent lamps 2300 W HV halogen lamps 2000 W Electronic transformers 1500 W Inductive transformers 1000 VA HV LED lamps typ 400 W Compact fl lamp typ 400 W Fluorescent lamps un...

Страница 17: ...vice detects motions constantly Remove interference sources if possible Reduce sensitivity Limit detection area Cause 2 On for 2 hours Continuous on or On for 100 hours is activated Switch on automati...

Страница 18: ...eme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 82593212 12 01 2017 18...

Отзывы: