FW2-FLOOD

 

FW2- FLOOD 8F/9F 

Wireless Flood Detector   

 

 

ELECTRONIC ENGINEERING LTD.

 

 

INSTALLATION INSTRUCTIONS 

 
 
 
 
 
 
 

P/N 7108149 Rev A D.Z

 

 

INTRODUCTION 

The FW2-FLOOD is an advanced Flood sensor 
with integrated RF transceiver designed to be a fully 
supervised low-current device  
The FW2-FLOOD is a part of the FREEWAVE2 
which is a supreme wireless line of devices that 
uses an advanced 2way RF transceiver combined 
with an intelligent communication protocol. 
A built-in terminal connection for an external wired 
sensor applies in this device.  
 
FW2-FLOOD uses smart message control, which 
verifies that all messages are successfully 
transmitted, so that no Flood event will be 
uninformed to the system. 
Each FW2-FLOOD has a unique factory set ID 
code (24bit) which by registration is set into 
memory of the paired FREEWAVE2 
TRANSCEIVER, enabling more secured

 

communication

 

and devices to be remotely 

controlled from a specific transceiver.   

 

 

 

FEATURES 

  State-of-the-art 2 way wireless security system 

  Freewave2 advanced & secured RF protocol 

  Low current Technology 

  Powered by a single 3V Lithium battery 

  Battery life: more than 5 years 

  Frequency: 4F (433 MHz),8F (868 MHz), 9F 

(916 MHz)          

  Tamper Open/Close transmission 

  Supervision transmission 

  Battery status send on every transmission 

  Range up to 500m on open space. 

  Unique ID number 

  Front and back tamper. 

  Alarm trigger by the wired contact sensor which 

is located at the end of the wired cable       

  Wired terminal for wire cable sensor connection  

 

4

 

 

5

 

 

6

 

OPERATION 

The Wireless Flood detector transmits the 
following events data: 

 
SUPERVISION

 - a periodical transmission time 

which is configurable 

indicates detector’s 

presence. 
 

ALARM

 - Alarm transmission triggered by Golden 

contacts pins located at the end of the external 
cable , The fluid has to reach the two exposed 
golden contacts  

 
LOW BAT

 

– Whenever the battery reaches a pre-

set low level (~2.4V) Battery Low signal will be 
sent with the next scheduled message 
(Supervisor, Alarm, etc.). 
 

TAMPER

 

– Whenever the FW2-FLOOD cover is 

removed or tore off wall, a message will be 
transmitted with “Tamper” signal. 
 

 

FIG. 1 - REMOVAL OF FRONT COVER 

 

 

 

FIG. 2 - BATTERY PLACEMENT 

 

 

7

 

 

8

 

 

9

 

Fig. 3 - CIRCUIT LAYOUT 

                           

 

 

FIG. 4 

– MOUNT FORM   

 

 

 

Fig. 5 - KNOCKOUT HOLES

 

   

 

10

 

 

11

 

 

12

 

MOUNTING THE DETECTOR 

 

Before starting to install and work with this device, 
please read the Safety Instructions. 

1.

  

Scope of delivery

 

FW2-FLOOD Wireless Unit, Flood Sensor Unit, (a) 
Screws for mounting the Units, (b) plugs, (c) Screw for 
locking the cover, (d) Battery. 

2. Installation Instruction

 

A. 

Mount the Flood sensor unit. 

B. 

To remove the front cover, unscrew the holding 
screw (Fig.1), insert a flat screwdriver in the 
slot between the front and the bottom while 
pushing and twisting it gently until the front 
cover is disengaged. (Fig. 1) 

C. Remove Printed Circuit board from the unit base 
D. Mount the base at 60cm above the sensor (Fig. 4), 

 

E. place all 3 screws (Fig.5) and make sure you tighten the 

tamper screw (the middle screw) easily, so the back 
tamper switch will press the switch successfully when 
PCB is placed back - over winding may result in false 
mechanical adaptation and lack of tamper press 

 

 
 

 
 

 

 
 
 

F. Install the Printed Circuit board back into the base of 

the wireless unit. 

G. Connect the two wires coming form the sensor to the 

Terminal block (Fig

 4). 

The fluid has to reach the two 

exposed Golden contacts at the bottom side of the 
sensor in order to give an alarm 

 

 

Use only the supplied screws and plugs.  

H

. Install battery (Fig.2) according to the polarity (-) (+) 
indications. 

 

 

Risk of explosion if battery is replaced by an incorrect 

type.  

      Use only batteries delivered by the supplier. 

 I

. Place the cover by inserting it back in the appropriate    

 

  

closing pin and screw the holding screw. 

 
 
  
     

 
 

 

ID REGISTRATION 

Refer to the system transceiver’s installation instructions 
and follow the procedure given there for “learning” detector 
IDs.  
Place battery as instructed & wait until start up LED stops 
blinking. 
Make sure that the transceiver is on learning mode 
according to control panel installation instruction. 
Generate a transmission by pressing and releasing tamper 
switch - this will start the "learn" data transmitting by the 
device to the control panel transceiver.  
Note the LED indications on the device:  

  Green/Red LED flashes alternately 

– for 5 sec     

FLOOD was registered successfully cover may 
be closed only after verification with control 
panel. 

  Green LED blinks periodically 

– 

Device was not sighed into FW2-TRANSCIVER.   
Repeat registration process 

  Red LED blinks 

– for over 20sec 

Battery voltage is critically low.  
Replace battery

 

 

 

 

 

 

 

Antenna

 

Contacts 
wire cable 
Input 

 

Battery

 

Tamper

 

Use for flat wall 
mounting 

 

Place the Flood 
unit near this 
marking

 

(Do not over tighten) 

 