1
2
3
FW2-FLOOD
FW2- FLOOD 8F/9F
Wireless Flood Detector
ELECTRONIC ENGINEERING LTD.
INSTALLATION INSTRUCTIONS
P/N 7108149 Rev A D.Z
INTRODUCTION
The FW2-FLOOD is an advanced Flood sensor
with integrated RF transceiver designed to be a fully
supervised low-current device
The FW2-FLOOD is a part of the FREEWAVE2
which is a supreme wireless line of devices that
uses an advanced 2way RF transceiver combined
with an intelligent communication protocol.
A built-in terminal connection for an external wired
sensor applies in this device.
FW2-FLOOD uses smart message control, which
verifies that all messages are successfully
transmitted, so that no Flood event will be
uninformed to the system.
Each FW2-FLOOD has a unique factory set ID
code (24bit) which by registration is set into
memory of the paired FREEWAVE2
TRANSCEIVER, enabling more secured
communication
and devices to be remotely
controlled from a specific transceiver.
FEATURES
State-of-the-art 2 way wireless security system
Freewave2 advanced & secured RF protocol
Low current Technology
Powered by a single 3V Lithium battery
Battery life: more than 5 years
Frequency: 4F (433 MHz),8F (868 MHz), 9F
(916 MHz)
Tamper Open/Close transmission
Supervision transmission
Battery status send on every transmission
Range up to 500m on open space.
Unique ID number
Front and back tamper.
Alarm trigger by the wired contact sensor which
is located at the end of the wired cable
Wired terminal for wire cable sensor connection
4
5
6
OPERATION
The Wireless Flood detector transmits the
following events data:
SUPERVISION
- a periodical transmission time
which is configurable
indicates detector’s
presence.
ALARM
- Alarm transmission triggered by Golden
contacts pins located at the end of the external
cable , The fluid has to reach the two exposed
golden contacts
LOW BAT
– Whenever the battery reaches a pre-
set low level (~2.4V) Battery Low signal will be
sent with the next scheduled message
(Supervisor, Alarm, etc.).
TAMPER
– Whenever the FW2-FLOOD cover is
removed or tore off wall, a message will be
transmitted with “Tamper” signal.
FIG. 1 - REMOVAL OF FRONT COVER
FIG. 2 - BATTERY PLACEMENT
7
8
9
Fig. 3 - CIRCUIT LAYOUT
FIG. 4
– MOUNT FORM
Fig. 5 - KNOCKOUT HOLES
10
11
12
MOUNTING THE DETECTOR
Before starting to install and work with this device,
please read the Safety Instructions.
1.
Scope of delivery
FW2-FLOOD Wireless Unit, Flood Sensor Unit, (a)
Screws for mounting the Units, (b) plugs, (c) Screw for
locking the cover, (d) Battery.
2. Installation Instruction
A.
Mount the Flood sensor unit.
B.
To remove the front cover, unscrew the holding
screw (Fig.1), insert a flat screwdriver in the
slot between the front and the bottom while
pushing and twisting it gently until the front
cover is disengaged. (Fig. 1)
C. Remove Printed Circuit board from the unit base
D. Mount the base at 60cm above the sensor (Fig. 4),
E. place all 3 screws (Fig.5) and make sure you tighten the
tamper screw (the middle screw) easily, so the back
tamper switch will press the switch successfully when
PCB is placed back - over winding may result in false
mechanical adaptation and lack of tamper press
F. Install the Printed Circuit board back into the base of
the wireless unit.
G. Connect the two wires coming form the sensor to the
Terminal block (Fig
4).
The fluid has to reach the two
exposed Golden contacts at the bottom side of the
sensor in order to give an alarm
Use only the supplied screws and plugs.
H
. Install battery (Fig.2) according to the polarity (-) (+)
indications.
Risk of explosion if battery is replaced by an incorrect
type.
Use only batteries delivered by the supplier.
I
. Place the cover by inserting it back in the appropriate
closing pin and screw the holding screw.
ID REGISTRATION
Refer to the system transceiver’s installation instructions
and follow the procedure given there for “learning” detector
IDs.
Place battery as instructed & wait until start up LED stops
blinking.
Make sure that the transceiver is on learning mode
according to control panel installation instruction.
Generate a transmission by pressing and releasing tamper
switch - this will start the "learn" data transmitting by the
device to the control panel transceiver.
Note the LED indications on the device:
Green/Red LED flashes alternately
– for 5 sec
FLOOD was registered successfully cover may
be closed only after verification with control
panel.
Green LED blinks periodically
–
Device was not sighed into FW2-TRANSCIVER.
Repeat registration process
Red LED blinks
– for over 20sec
Battery voltage is critically low.
Replace battery
Antenna
Contacts
wire cable
Input
Battery
Tamper
Use for flat wall
mounting
Place the Flood
unit near this
marking
(Do not over tighten)