                                                                                             Rescue Life - User Manual                                                           Rev. 3.1 

 

 
 

6

 

 

SYMBOLS USED

 

The symbols below may be found in this manual or in rear sticker or accessories of 

Rescue LIFE

 defibrillator.  

Symbol

 

Description of symbol

 

 

Identification of device 

 

Serial Number of device 

 

Manufacturer identification  

 

Date of production  

 

Defibrillation-proof BF type  

 

Defibrillation-proof CF type  

 

Alternated  

 

Class II 

 

Danger of an electrical shock 

 

The  user  must  to  consult  the  instructions  for  use  for 
important  cautionary  information  such  as  warnings  and 
precautions  that  cannot,  for  a  variety  of  reasons,  be 
presented on the medical device itself. 

                 

Indicates the need for the user to consult the instructions 
for use. 

 

Do not use AED mode on NEWBORN 

Содержание Rescue LIFE

Страница 1: ...Rescue LIFE EXTERNAL BIPHASIC DEFIBRILLATOR and MONITOR USER MANUAL ELPRO S r l Strada del Rondello 5 10028 Trofarello TO ITALY Rev 3 1 Distributed by...

Страница 2: ...Distributed by Rescue Life User Manual Rev 3 1...

Страница 3: ...ING ON 5 ELECTRICAL SAFETY GUIDELINES 5 SYMBOLS USED 6 INTRODUCTION 8 UNPACKING AND INSPECTING 8 DEVICE OPERATION AND STORAGE GUIDELINES 8 8 CLEANING AND MAINTENANCE 9 CONNECTING TO POWER 10 BATTERY C...

Страница 4: ...32 DEFIBRILLATION MODE 33 DEFIBRILLATOR PROCEDURE IN MANUAL MODE 34 DEFIBRILLATOR PROCEDURE IN ADVISORY MODE ADV 35 AUTOMATED EXTERNAL DEFIBRILLATION AED 36 INDICATIONS FOR USE 36 ECG ANALYSIS ALGORI...

Страница 5: ...SE SCREEN 60 DATA RETRIEVAL 61 DATE AND TIME SETUP 62 PRINTING AND PAPER CHANGE 62 AUTO TEST 63 RESCUE LIFE CHECKLIST 65 APPENDIX A 66 CLINICAL INFORMATION 66 How does biphasic waveform defibrillate 6...

Страница 6: ...al Rev 3 1 V APPENDIX D 76 TECHNICAL FEATURES 76 APPENDIX E INSTRUCTION FOR USE FOR DISPOSABLE MULTIFUNCTION ELECTRODES FOR DEFIBRILLATOR 81 OPERATING INSTRUCTION 83 DECLARATION OF EC CONFORMITY 88 AP...

Страница 7: ...e information and procedures related to all features and options of the RESCUE LIFE monitor defibrillator Your RESCUE LIFE monitor defibrillator may not have all of these features or optional Please r...

Страница 8: ...our customers to ensure that the appropriate person s within their organization have access to this information including general safety information which are given in this manual GENERAL Assure your...

Страница 9: ...DENTALLY CREATING CURRENT PATH FOR THE DEFIBRILLATION IMPULSE THE PARTS OF THE PATIENT BODY SUCH AS THE HEAD OR LIMBS MUST NOT BE IN TOUCH WITH METAL PARTS BED FRAMES OR STRETCHERS THE PATIENT MUST NO...

Страница 10: ...IL DO NOT CLEAN WITH KETONES OR OTHER FLAMMABLE AGENTS DO NOT AUTOCLAVE OR STERILIZE THIS DEFIBRILLATOR OR ACCESSORIES UNLESS OTHERWISE SPECIFIED USE CARE WHEN OPERATING THIS DEVICE CLOSE TO OXYGEN SO...

Страница 11: ...MONITOR SCREEN THE OPERATOR HAS TO CONNECT IMMEDIATELY THE AC POWER CORD TO AN OUTLET ELECTRICAL SAFETY GUIDELINES Use only the original power cord during recharging The right value for the AC power...

Страница 12: ...nufacturer identification Date of production Defibrillation proof BF type Defibrillation proof CF type Alternated Class II Danger of an electrical shock The user must to consult the instructions for u...

Страница 13: ...Rev 3 1 7 Follow local regulations on battery disposal or recycling CE Mark Notified Body identification Fragile content handle with care on the package To keep dry and to not exposure to weathering o...

Страница 14: ...S Do not operate or store the device in conditions that are beyond the following specified limits Operating Conditions Temperature 5 C to 46 C Humidity 10 to 95 non condensing Storage Conditions witho...

Страница 15: ...SSORIES WITH BLEACH BLEACH DILUTION OR PHENOLIC COMPOUNDS DO NOT USE ABRASIVE OR FLAMMABLE CLEANING AGENTS DO NOT ATTEMPT TO STERILIZE THIS DEVICE OR ANY ACCESSORIES UNLESS OTHERWISE SPECIFIED IN ACCE...

Страница 16: ...d is disconnected from an AC outlet or from the defibrillator The internal Lithium Ion battery is rechargeable and intended to be used for standby operation A new completely charged battery provides a...

Страница 17: ...To see the battery charge status switch on the device with pads connector not attached When the battery value is under 10 a message appears on display CHARGE BATTERY OR SYSTEM WILL SHUT OFF Insert th...

Страница 18: ...oduct name Product serial number Date of purchase Name of sales representative Information of customer and a brief description of the problems encountered All of the service works for the product must...

Страница 19: ...prevent possible electrical and mechanical discrepancies When the device is not functioning properly it has to be submitted for maintenance immediately When any abnormalities are found in the device o...

Страница 20: ...rrence of the ECG R peak The RESCUE LIFE in the basic configuration has only the manual mode available and the ECG monitoring can be done by defibrillation pads 1 trace or by 5 wire ECG monitoring cab...

Страница 21: ...y means of Synchronous defibrillation cardioversion patients with ECG s that show the presence of Atrial Fibrillation It is designed to monitor patient ECG by means of the multiple signal acquisition...

Страница 22: ...ess Absence of normal breathing and Lack of detectable pulse Rhythms need a shock Synchronous defibrillation the shock delivery is synchronized with the R peak of the patient s ECG In synchronous defi...

Страница 23: ...e disconnected the battery status and clock set up screen will appear In this case to start ECG monitoring press F1 key To access the DATA BASE only on the AED models press F2 key MEMORY To switch off...

Страница 24: ...with the standard pads press both push buttons on the pads handles FUNCTION KEYS F1 F5 These keys are used for different functions according to the screen where they are used KEY INITIAL SCREEN OPERAT...

Страница 25: ...hted it informs that connection to AC line is carried CASE B When the connection to AC line is removed the LED will switch off Indicator LED BATTERY CHARGE CASE A CASE B CASE A When the LED indicator...

Страница 26: ...pull the lead lever and turn left the connector ECG PATIENT CABLE ECG patient cable input RESCUE LIFE displays 3 6 or 12 traces SpO2 INPUT optional When the SpO2 sensor is connected saturation values...

Страница 27: ...ith the defibrillation paddles disconnected Battery status and clock are shown Using function keys it is possible to enter in different screens START F1 to enter in Operational screen MEMORY F2 to ent...

Страница 28: ...nual Rev 3 1 22 OPERATIONAL SCREEN At power ON if the paddles are connected the RESCUE LIFE will start the operation If the paddles are not connected the start screen will be displayed Press START F1...

Страница 29: ...UE LIFE socket otherwise system will shout down automatically in 2 minutes During this time defibrillation functions are disabled DATE AND TIME date and time are shown OPERATION MODE operation mode se...

Страница 30: ...printing PACER F3 it allows to enter in Pacemaker screen optional SYNC F4 it allows to activate and deactivate sync mode MENU F5 it allows to open menu SET UP MENU The START UP menu is accessible pres...

Страница 31: ...efers to the bandwidth of the signal In MONITOR mode bandwidth in 0 6 Hz to 40 Hz in DIAGNOSTIC mode bandwidth is 0 05 Hz to 120 Hz Notch filter is always active If the ECG trace is acquired by defibr...

Страница 32: ...ator is charged using this mode the standard impedance of 50 ohm is assumed ELPRO S r l recommended to make one functional check preventive maintenance and electrical safety test at least once a year...

Страница 33: ...ectrodes with expired Use By date codes Disposable electrodes are intended for a single use For best ECG monitoring results use silver silver chloride Ag AgCl electrodes Other types of electrodes will...

Страница 34: ...Distributed by Rescue Life User Manual Rev 3 1 28 Precordial lead electrodes sites for the 10 wires ECG cable Figure I II III aVR aVL aVF V1 V2 V3 V4 V5 V6 derivations on frontal and orizzontal planes...

Страница 35: ...ation The American Heart Association has identified the following as critical links in the chain of survival from cardiac arrest Early access Early CPR by first responders or bystanders Early defibril...

Страница 36: ...for treating atrial fibrillation atrial flutter paroxysmal supraventricular tachycardia and in relatively stable patients ventricular tachycardia The biphasic defibrillation waveform used in this dev...

Страница 37: ...ne near the top of the package Remove the pads from the package and follow the directions and diagram showing proper defibrillation pad placement located on the defibrillation pad package The correct...

Страница 38: ...ng them Remove the coating only when the electrode is ready to be applied Put the electrodes with the adhesive side of the patient s skin Place the electrodes as shown in the diagram The placement of...

Страница 39: ...SCUE LIFE automatically analyze heart rhythm In ADVISORY mode ADV RESCUE LIFE only analyzes and suggest if patient needs defibrillation after that users have to choose energy value charge defibrillato...

Страница 40: ...ck 9 The shock has to be released within 25 sec from the charge completed after 25 sec the RESCUE LIFE will discharge internally 10 If the defibrillation is not required press the DISARM F1 key to dis...

Страница 41: ...tart charging 5 If you are using disposable pads press the CHARGE button on the device panel to start charging 6 On the screen the charge status bar indicates that the charging procedure is on at the...

Страница 42: ...in basic life support CPR AED The device is indicated for emergency treatment of victims exhibiting the following symptoms of a sudden cardiac arrest un consciousness absence of normal breathing and...

Страница 43: ...nded by the European Resuscitation Council ERC 1 1 European Resuscitation Council ERC Guidelines for cardiopulmonary resuscitation CPR European Resuscitation Council vol 81 2010 Upon detecting a shock...

Страница 44: ...e display below status battery indicator It means that device will record for 1 minute the ECG trace on the USB FLASH STORAGE 3 If RESCUE LIFE recognizes a shockable rhythm it automatically will charg...

Страница 45: ...User Manual Rev 3 1 39 DO NOT TOUCH THE PATIENT DURING HEART RHYTHM ANALYSIS DO NOT TOUCH THE PATIENT DURING DEFIBRILLATION TURNING OFF THE DEFIBRILLATOR BEFORE RECORDING IS FINISHED IT WILL PRODUCE...

Страница 46: ...Distributed by Rescue Life User Manual Rev 3 1 40 SEMIAUTOMATIC AED MODE FLOW CHART...

Страница 47: ...at the device is doing an analysis of the patient s ECG SHOCK ADVISED Indicates that the patient has a shockable ECG rhythm PRESS THE RED BUTTON NOW Indicates that the user have to press the SHOCK but...

Страница 48: ...probability of successful pacing or of skeletal muscle activity The failure to successfully pace a patient is not a reliable indicator of pacemaker performance In the same way the patient s muscular...

Страница 49: ...set pacing parameter KEY FUNCTION RYTHM F1 Press key and use the Speed Dial to change the value to set the pacing rhythm CURRENT F2 Press key and use the Speed Dial to change the value to set the pac...

Страница 50: ...d positioned below the right clavicle Lateral plate positioned on the middle axillary line at the height of his left nipple position V6 PACING PROCEDURE 1 Switch on the device pressing the ON OFF butt...

Страница 51: ...light absorption by that blood changes during the pulse plethysmography A pulse oximeter determines SpO2 by passing red and infrared light into an arteriolar bed and measuring changes in light absorp...

Страница 52: ...eusable sensors may be reused on different patients after cleaning and disinfecting Do not use other sensors aside from the ones recommended Before using carefully read the sensor directions for use i...

Страница 53: ...Medical designed the Advantage A to meet the needs of the most challenging clinical application with internal automatic modes low voltage communication protocols the lowest power consumption in the in...

Страница 54: ...ally referred to as the mean arterial pressure MAP As cuff deflation continues the diastolic pressure can be determined based upon the rapidly diminishing amplitude of the pressure fluctuations Thus s...

Страница 55: ...IZED BY ELPRO S R L Accuracy of any blood pressure measurement may be affected by the position of the subject his or her physical condition and use outside of the operating instructions detailed in th...

Страница 56: ...material of the cuff Petechia a minute reddish or purplish spot containing blood that appears in the skin formation or Rumple Leede phenomenon multiple petechia on the forearm following the applicatio...

Страница 57: ...g The cuff should fit snug to the patient s arm for maximum oscillometric signal quality An appropriate sized cuff should be placed on the non dominate arm where the lower edge of the cuff is located...

Страница 58: ...surements from both arms are same When a cuff is going to be positioned on a patient for an extended length of time be sure to occasionally check the limb for proper circulation ACTIVATION AND OPERATI...

Страница 59: ...SYS DIA MEAN SET F4 to enter the NIBP set up menu EXIT F5 to exit the NIBP and return to the defibrillator functions NIBP SET UP MENU Pressing the SET F4 key the NIBP set up menu is displayed To modi...

Страница 60: ...yed and printed if the automatic print mode is active In manual print mode press the PRINT F2 key to get the hardcopy of the measurement For an automatic measurement enter the set menu select the auto...

Страница 61: ...n The patient may have been moving too much Check that the cuff is in the correct position Check that the correct size cuff is being applied EC 4 Exceeded measurement time limit Corrective Action The...

Страница 62: ...he hose connections are not damaged or loose EC 88 Safety Timeout Corrective Action Check the patient Check that the cuff is in the correct position The patient may have been moving too much Take anot...

Страница 63: ...ppendix 3 Specifications Method of Measurement Oscillometric Diastolic values correspond to Phase 5 Korotkoff sounds Blood Pressure Range Systolic ADULT 40 260 mmHg PEDIATRIC 40 160 mmHg NEONATE 40 13...

Страница 64: ...Previous Systolic 30 mmHg NEONATE Previous Systolic 20 mmHg Clinical Accuracy Meets accuracy requirements of ANSI AAMI SP10 2002 and EN1060 4 2004 Pressure Transducer Accuracy 3 mmHg between 0 mmHg an...

Страница 65: ...abort a BP measurement if cuff pressure exceeds 300 mmHg Adult Pediatric modes or 150 mmHg Neonate mode at any time the cuff has been inflated for 180 seconds above 15 mmHg Adult Pediatric modes or 90...

Страница 66: ...recording is available only in AED mode The recording will start automatically each time the ANALISYS starts When RESCUE LIFE is recording on the top side of the display below battery status indicato...

Страница 67: ...t recent file Pressing the DOWN F1 key the next 10 files will be shown Pressing the TOP F2 key the previous 10 file will be shown Pressing the Speed Dial will select a file from the list and rotating...

Страница 68: ...int mode enter the menu and select MANUAL or AUTOMTIC mode from PRINT MODE MANUAL MODE To start printing press the PRINT F2 key The hardcopy will start with the set up parameters and with the ECG trac...

Страница 69: ...g the leads I II III While print is in progress enter the menu and select the successive derivations aVR aVL aVF Repeat until you have printed all leads Then stop printing AUTO TEST RESCUE LIFE is equ...

Страница 70: ...ounds some fault the system will indicate it Note the error code and communicate it to the authorized technical service Pressing the PRINT F3 you can print the test report EVERY REPORT HARDCOPY REFERS...

Страница 71: ...ctor and the cable Make sure the paddles are clean and free of traces of gel To test the paddles switch on defibrillator set an energy of 1 Joule charge the capacitor by pressing the buttons on the pa...

Страница 72: ...RILLATE For defibrillation to be successful a sufficient amount of electrical current must be delivered to the heart muscle How to deliver the electrical current to the heart muscle is the core techni...

Страница 73: ...iaison Committee On Resuscitation ILCOR average adult impedance is 70 80 ohms Defibrillation energy should be designed to optimize the delivery of current over a wide range of patient impedances Too m...

Страница 74: ...e patient Biphasic technology increases the duration of current flow for patients with high impedance When escalating energy for example 150J to 180J it delivers the electrical energy with higher volt...

Страница 75: ...Distributed by Rescue Life User Manual Rev 3 1 69...

Страница 76: ...ween monophasic and biphasic waveform is qualitatively similar but varies quantitatively for different parameter values The fundamental difference is that first phase of the biphasic pulse acts as a p...

Страница 77: ...t higher rates resulting in more patients who achieved a return of spontaneous circulation Although survival rates to hospital admission and discharge did not differ discharged patients who had been r...

Страница 78: ...n 2000 102 1780 1787 6 Steven L Higgins et al A comparison of biphasic and monophasic shocks for external defibrillation Prehospital Emergency Care 2000 4 305 313 7 J P KEENER T J LEWIS The Biphasic M...

Страница 79: ...RLFS 008 RLFS 009 RLFS 0010 1 Standard Electrodes for defibrillation 5 leads ECG cable 10 leads ECG cable Adult SpO2 sensor Pediatric SpO2 sensor AC Adapter Disposable electrodes cable Adult disposab...

Страница 80: ...ion electrodes for a maximum of 230 Joule 150J 25ohm 230J 50ohm 230J 75ohm 230J 100ohm 230J 125ohm 230J 150ohm For impedance value of 40ohm or less the 230J 175ohm maximum energy is 150J If the energy...

Страница 81: ...displayed on the screen The device can not automatically set the sync mode In the sync mode the device releases the defibrillation shock only when the R peak in the QRS complex is detected The maximum...

Страница 82: ...filter base line Traces 3 3 1 I II III aVR aVF aVL V with 5 wires patient cable Traces 3 3 6 I II III aVR aVF aVL V1 to V6 with 10 wires patient cable Heart rate Digital readout on the display from 2...

Страница 83: ...ry internal rechargeable charging time maximum 3 hours capacity 150 shocks at 230 J battery fully charged Manual mode Energy range 1 230 J from 1 10 J in 1 J steps from 10 230 J in 10 J steps Commands...

Страница 84: ...pts Shockable rhythms VF with amplitude 0 15 mV and VT with rhythm 150 bpm Sensitivity Shockable rhythm VF 95 Shockable rhythm VT 75 Specificity Normal sinusoidal rhythm 99 Asystole and other non shoc...

Страница 85: ...eonatal 20 100 mmHG PR RANGE 30 220 BPM PR Accuracy 2 or 3 bpm Transducer Accuracy 3 mmHg over full range in operating conditions Operating Modes Manual Long Term Automatic Stat Service Auto Interval...

Страница 86: ...nmental Temperature without Disposable Multifunction Electrodes for defibrillator Operational 5 46 C Storage 20 50 C Relative humidity 10 95 Temperature without Disposable Multifunction Electrodes for...

Страница 87: ...DISPOSABLE MULTIFUNCTION ELECTRODES FOR DEFIBRILLATOR Disposable Multifunctional Electrodes for Defibrillator defibrillation synchronized stimulation transcutaneous cardiac stimulation ECG monitoring...

Страница 88: ...n Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Circulation 2010 122 S640 S946 Journal of the American Heart Association Editor Mary Fran Hazinski RN...

Страница 89: ...le paddles CONTRAINDICATIONS PROGETTI disposable multifunction electrodes for adults are generally contraindicated in patients younger than 8 years old 2 weighing less than 25kg 3 4 but can be used if...

Страница 90: ...evere arrhythmic disease may develop The points where it is possible to apply the adhesive electrodes are listed in PLACEMENT AND POLARITY Uncover the chest and prepare the skin Remove excessive hair...

Страница 91: ...therapy it is not relevant which electrode pad apex sternum is placed in one of the two positions 2 Regarding the polarity of the electrodes in unique version adult pediatric follow the directions on...

Страница 92: ...e adhesive pads Do not use the multifunction electrodes if the connector the cable or the clips appear to be damaged Check on the operating instructions of the defibrillator at which safety distances...

Страница 93: ...on for use We recommend to report opportunely any malfunction or defect of the product to ELPRO S r l or PROGETTI S r l DESCRIPTION OF USED SYMBOLS 0068 EC Mark Notified Body Identification Manufactur...

Страница 94: ...ISO 14971 2012 EN ISO 15223 1 2012 MEDDEV 2 7 1 Rev 4 MEDDEV 2 12 1 Rev 8 MEDDEV 2 12 2 Rev 2 SERIAL NUMBER WE HEREWITH DECLARE THAT THE ABOVE MENTIONED PRODUCT S MEET THE TRANSPOSITION INTO NATIONAL...

Страница 95: ...ELPRO S r l This warranty does not cover any accessories ELPRO S r l will replace damaged parts and components according to its option ELPRO S r l will replace cost free those parts and components un...

Страница 96: ......

Страница 97: ......

Страница 98: ...Rescue Life User Manual vers 3 1 ELPRO S r l Strada del Rondello 5 10028 Trofarello TO ITALY www elpromedical com Distributed by...

Отзывы: