4) Sets the ‘minimum’ position value to 128 (50%)
7) Increments the ‘minimum’ position value
Use the ‘2’, ‘5’ and ‘8’ keys to adjust the ‘maximum’ position the for the
selected analog output. This sets the voltage that will be sent out from the
Br-EFB when you give it a ‘100%’ position command through the DMX-512 or
AutoDownload file. The default analog output (when set to 255/0FFh) is 10 vdc.
This will automatically force the output to the ‘100%’ position
. For cylinders and
electric actuators, this is usually the fully extended position. You can adjust the
analog output to anywhere between 0 and 10 volts. If you adjust the ‘maximum’
to a voltage that is lower than the ‘minimum’, this is perfectly acceptable, and is
the easiest way to reverse the motion of an actuator.
The keys are used as follows:
2) Decrements the ‘maximum’ position value
5) Sets the ‘maximum’ position value to 128 (50%)
8) Increments the ‘maximum’ position value
You can then use the ‘-’, ‘+’, ‘3’, ‘6’ and ‘9’ keys to move the analog output
over the full range of output (the full range is set by the values in the ‘minimum’
and ‘maximum’ columns). You can use these keys to test your adjustments. The
Br-EFB does this by using these keys to adjust the ‘Jog’ value. When you are
done adjusting this output, you will want to make sure you clear the ‘Jog’ value,
or the analog output will remain locked at the last value set in the ‘Jog’ column.
You can do this by hitting the ‘-’ key twice, or hitting the ‘3’ (decrement ‘Jog’
value) one more time after it is already at zero.
If you have console or other way of moving the channel you are adjusting,
you will probably not use this feature and use the console instead.
The keys are used as follows:
‘-’)
!
Sets the ‘Jog’ position value to zero (a 2nd time clears ‘Jog’)
‘+’ or ‘=’)
!
sets the ‘Jog’ position value to 100%
2) Decrements the ‘Jog’ position value
5) Sets the ‘Jog’ position value to 128 (50%)
8) Increments the ‘Jog’ position value
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-EFB Manual / May 22, 2018 3:28 PM / page 89 of 142
4
This ‘forcing’ feature can be toggled on and off using the command ‘a) toggle Auto force to 0% or 100%’, or if you entered this
mode while holding down the <control> key while you pressed the ‘u’ key.