These four Yellow LEDs show the output level on all four of the
Compliance Feedback inputs. As you push on a compliant axis, you will
see these LEDs turn on sharply and fade out as the Compliance Feedback
effect fades away. These LEDs are not directly connected to the analog
Compliance Feedback inputs.
Z) ServoValve Output Indicators
(One Red/Green LED per axis for Four Red/Green LEDs in total)
These four Red/Green LEDs show the output level on all four of the
+/-10vdc ServoValve/Motor Controller outputs. You will see these LEDs
fade in and out as the signals are sent to the ServoValves/Motor
Controllers. When the voltage sent to a ServoValve/Motor Controller output
is below zero, the LED lights Red. For voltage sent to a ServoValve/Motor
Controller output is above zero, the LED lights Green. The further away
from zero that the ServoValve/Motor Controller voltage is, the brighter the
LEDs will glow.
Note that when the External Output Enable Input is not enabled (no
voltage applied), the voltage from the 'battery' terminals are connected
through electromechanical relays to all four of the ServoValve/Motor
Controller outputs. Since the entire Br-EFB is bypassed when in this mode,
the ServoValve/Motor Controller Output Indicator LEDs will not light to
show the battery voltage.