17
Set Date/Time („S‟, 53H)
PC to GS1100
ENQ-M#-
„S‟
GS1100 to PC
ACK*
PC to GS1100
STX-
date/time
-ETX-BCC
GS1100 to PC
ACK/(NAK)**
PC to GS1100
EOT
Date/time field has the following format:
YYYYMMDDhhmmss
, where:
YYYY
- year,
MM
- month,
DD
- date,
hh
- hour,
mm
- minutes,
ss
- seconds.
*The GS1100 will accept this command regardless of whether there is any data in the log
database or not.
**The GS1100 will accept any date/time data, even if it is invalid (for example, even with
the month set to 13). Use new “T” command to verify if new date and time were actually
set.
Get date/time („T‟, 54H)
PC to GS1100
ENQ-M#-
„T‟
GS1100 to PC
STX-
date/time field
*- ETX-BCC
PC to GS1100
ACK/(NAK)
GS1100 to PC
EOT
Date/time field has the following format:
YYYYMMDDhhmmss
, where:
YYYY
- year,
MM
- month,
DD
- date,
hh
- hour,
mm
- minutes,
ss
- seconds.
Download database data („I‟, 49H)
PC to GS1100
ENQ-M#-
„I‟
GS1100 to PC
STX-
first record data
- ETX-BCC
PC to GS1100
ACK/(NAK)
GS1100 to PC
STX-
next record data
- ETX-BCC
PC to GS1100
ACK/(NAK)
More records…
…and acknowledgements
GS1100 to PC
STX-
last record data
- ETX-BCC
PC to GS1100
ACK/(NAK)
GS1100 to PC
EOT