background image

FACE RECOGNITION TERMINALS

R20-FACE (8W/8T/Thermometer/SE)

OPERATIONS MANUAL

Содержание R20-Face (8T)

Страница 1: ...FACE RECOGNITION TERMINALS R20 FACE 8W 8T Thermometer SE OPERATIONS MANUAL...

Страница 2: ...ometer R20 Face 8W SE R20 Face 8T SE R20 Face 8W Thermometer SE R20 Face 8T Thermometer SE Mount Wall Fare gate Wall Fare gate Wall Fare gate Wall Fare gate Thermometer Yes Yes Yes Yes Expanded memory...

Страница 3: ...LCD anti glare touchscreen Resolution 1080x800 pixels viewing angle 170 Built in with white and infrared light 2 0 MP viewing angle 95 8 focal length 5 75mm aperture F2 7 WDR RS 232 Wiegand 26 34 50 E...

Страница 4: ...installation diagrams All dimensions are in millimeters Fig 1 Dimensions and mounting holes marking for any R20 Face 8W modification Fig 2 Dimensions and mounting holes marking for any R20 Face 8T mo...

Страница 5: ...on of fare gate mounted modifications of R20 Face terminal The distance from the fare gate edge to the terminal location point is reference and may vary depending on the specific model of the fare gat...

Страница 6: ...with a cross section not thinner than flat copper two core cable with PVC insulation 2x1 5 or analog After turning on the terminal make sure that the voltage is 12 12 2V In case the voltage is less i...

Страница 7: ...Connection diagram to access control panel ACS 102 CE ACS 105 CE ACS 202 CE via Wiegand interface To reduce the interference effect on the Wiegand line the UTP 4x2x0 52 cable type is recommended...

Страница 8: ......

Страница 9: ...To reduce the interference effect on the Wiegand line the UTP 4x2x0 52 cable type is recommended Connection diagram to access control panel ACS 103 CE via Wiegand interface...

Страница 10: ...Connection diagram to access control panel ACS 102 CE ACS 105 CE ACS 202 CE via RS 232 interface...

Страница 11: ...RusGuard access control panels are equipped with RS 232 port Check the availability of these interfaces when ordering the panels To reduce the interference effect on the Wiegand line the UTP 4x2x0 52...

Страница 12: ...sGuardFaceConfig zip 2 Configure the 10 0 0 x network on the PC 3 Connect the PC to the terminal or to the same network 4 Run the utility click Check the Serial number should display the serial number...

Страница 13: ...he Edit button check the box next to No card types if your facility does not have separation of employee card types or select the desired type of key that will be used for biometrics Fig 6 If you use...

Страница 14: ...et Default in the Reader interface setting When connecting the terminal via RS 232 select the RS 232 item 3 if necessary configure other terminal settings such as Recognition type Recognition distance...

Страница 15: ...to the Access levels section Create a new access level and open the Add Access Point dialog Select the drawn up Pass schedule and enable the Multi Factor Authentication option 3 For the Card or Face m...

Страница 16: ...10 Fig 11 Access level settings for Card and Face mode Fig 10 Access level settings for Card and Face mode...

Страница 17: ...photo is not less than 320x240 the distance between the pupils is not less than 60 pixels the recommended head size in the frame is 70 horizontally subject to the recommended minimum resolution of the...

Страница 18: ...l regulations EAEU N RU RU 66 00720 19 dated October 25 2019 issued by the Testing Laboratory of the PLANTEST Limited Liability Company accreditation certificate RU 33071 000014 Certificate of Conform...

Страница 19: ...rules mechanical damage or traces of exposure to water and or aggressive substances damage caused by careless storage or transportation through the buyer s fault traces of unskilled interference in th...

Страница 20: ...ay Month Year _____________________ R20 Face 8W R20 Face 8T R20 Face 8W Thermometer R20 Face 8T Thermometer R20 Face 8W SE R20 Face 8T SE R20 Face 8W Thermometer SE R20 Face 8T Thermometer SE V1 0 10...