Weight reset and WEIGHT/PEAK switchover.
Resetting zero (semi-automatic zero)
Resets zero balance
In peak display this operation is used to zero the peak value, while in weight display it is used to correct
small shifts of the scale zero.
The gross weight reset command (weight display) is not executed in the following conditions:
Unstable weight (weight does not stabilize within 3 seconds after the reset command)
Gross weight, relative to the original zero calibration, greater (positive or negative) than 2% of the FS
Active tare
Switching display weight or peak
Weight/peak display switching
Turning off instrument
3 sec.
Instrument shutdown
Tare
Semi-automatic tare (autotare)
Performs autotara
The autotare command is not executed under the following conditions:
Unstable weight (weight does not stabilize within 3 seconds after the reset command)
Negative gross weight
Gross weight greater than maximum capacity
The semiautomatic tare is always locked, to cancel the tare you need to press the same key with the gross
weight below the minimum weighing threshold (20 divisions).
In peak display the key is not enabled.
Semi-automatic tare replaces any previously entered tare.
Manual tare
Tare setting
3 sec.
The manual tare is always locked, to cancel the tare, the same key must be pressed with the gross weight
below the minimum weighing threshold (20 divisions).
In peak display the key is not enabled.
The semiautomatic tare is added to any previously entered tare.