Settings menu for battery operation
With the instrument off, move jumper JP1 to the inside of the board (see installation manual) or hold down
the
key while pressing the
key.
Shutdown
instrument
PArAM SEr
ConSt CALibr
bAtt
tESt
4 sec.
Set value
StdbY
StAto
on
oFF
StdbY
Minutes after which the display is sent to standby
(value 0 to 9 min)
To not activate standby operation, the value 0 must be set.
If the standby function has been activated, the display is not completely turned off, but
scrolling dashes are displayed.
To exit standby, simply press any key or move the weight.
StAto
If ON means the instrument is operating connected to a battery so it enables low
battery check.
indication
if the battery needs to be recharged.
bAtt
The instrument will be turned off automatically:
If the supply voltage is less than 5.9V, in case only one cell is connected
If the supply voltage is less than 5.97V , in case 4 cells are connected
Viewing subdivisions
Entering the
function of the menu (only if jumper JP1 is enabled) displays the number of
subdivisions of the current weight. This display is indicated by intermittent flashing of the LEDs.
tESt
If the number of subdivisions is greater than 99999, the upper dashes are displayed.
Содержание WIN7
Страница 1: ...W I N 7 S o w a r e P 0 7 0 1 6 V e r s i o n e 0 3 Manuale Manual Handbuch ...
Страница 10: ...Pagina page Seite 8 ...
Страница 24: ...Pagina page Seite 22 ...
Страница 38: ...Pagina page Seite 36 ...
Страница 48: ......