Before proceeding with installation, fit a magnetothermal and differential switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening
distance of at least 3mm.
All the packaging materials must be kept out of reach of children since they are potential sources of danger.
The manufacturer declines all responsibility for proper functioning of the automated device if failing to use original
GIBIDI components and accessories suitable for the intended application.
When installation has been completed, always carefully check proper functioning of the system and the devices
used.
This instruction manual addresses persons qualified for installation of “live equipment”, therefore, good technical
knowledge is required exercised as profession in compliance with the regulations in force.
Maintenance must be performed by qualified personnel.
Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
This product has been designed and constructed solely for the use indicated in this document. Any other use may
cause damage to the product and be a source of danger.
Verify the intended end use and take the necessary safety precautions.
Use of the products for purposes different from the intended use has not been tested by the manufacturer and the
operations performed are therefore on full responsibility of the installer.
Mark the automated device with visible warning plates.
Warn the user that children and animals must not play or stand near the gate.
Adequately protect the danger points, for example, using a sensitive frame.
Check proper installation of the earthing system; connect all the metal parts of doors, gates, etc. and all the
system components equipped with earthing plate.
Exclusively use original spare parts for any maintenance or repair.
Do not make any modification to the components of the automated device unless expressly authorised by GIBIDI.
The gearmotors SL 800 allow easily and quickly automating small to medium-sized sliding gates of up to 800 kg.
The automated device with integrated control unit facilitates system certification in accordance with EN125453.
ELECTRICAL EQUIPMENT [1]
TECHNICAL DATA
1- Gearmotor; 220-230V power supply, 3x1.5mm² cable (comply with the current standards)
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- Flashing light signaller 2x0.75mm² cable
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm Power supply line to the control unit
220-230V, 50-60Hz, 3x1.5 mm² cable (comply with the current standards).
Supply voltage
Power absorbed
Current absorbed
Thermal cuout
Pick-up capacitor
Max speed
Max torque
Operating temperature
Degree of protection
Operating frequency (%)
Operator
Type
Irreversible electromechanical gearmotor
Type of oil / grease
A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two openings
%Fu =
x 100
A + C
A + C + P
Formula to calculate the
operating frequency
[28]
Max leaf weight
SL 820-830-840
220/230V 50-60Hz
MAX 350W
MAX 1.5A
140°C
10
µ
F
0,16 m/s
20 Nm
-20°C + 60°C
IP 45
60% (a 20°C)
GBD PH-02
800 Kg