9 - DIP SWITCH DIP1
OFF
STEP-BY-STEP
WITH STOP
ON
AUTOMATIC
Operation in response to the START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
STOPS
→
Ÿ
Gate open
CLOSES
→
Ÿ
During closing
STOPS
→
Ÿ
After a STOP
inverts the motion
→
Operation in response to the START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
UNINFLUENTIAL
→
Ÿ
Gate open
Reloads the automatic closing time if automatic closing
→
is enabled, otherwise it closes.
OFF
ON
TERMINAL 21
AS EDGE
Operation :
Ÿ
Gate closed
UNINFLUENTIAL
→
Ÿ
During opening
STOP
→
Ÿ
Gate open
UNINFLUENTIAL
→
Ÿ
During closing
STOP
→
Operation
Ÿ
Ÿ
During opening
Immediate motion inversion for 2s at low speed, when
→
contact is freed, the gate will continue with inverted movement at low speed.
Ÿ
Gate open
UNINFLUENTIAL
→
Ÿ
During closing
Immediate motion inversion for 2s at low speed, when
→
contact is freed, the gate will continue with inverted movement at low speed.
:
Gate closed
UNINFLUENTIAL
→
1_1
1_2
TERMINAL 21
AS STOP
1_3
1_4
AMPEROMETRIC STOP
SENSITIVITY
Very High sensitivity.
OFF
OFF
High sensitivity.
OFF
ON
Medium sensitivity.
ON
OFF
Low sensitivity.
ON
ON
1_5
1_6
PAUSE TIME
Automatic closing disabled.
OFF
OFF
10 seconds.
OFF
ON
30 seconds.
ON
OFF
60 seconds.
ON
ON
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
19
BE12
UK
9 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
1_7
Enables pre-flashing of 3 seconds before motor activation during opening and closing.
Disables gate phase shift time.
ON
OFF
PRE-FLASHING
1_8
1_9
GATE PHASE
SHIFT TIME
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 3 seconds.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Disables pre-flashing.
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 6 seconds.
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 9 seconds.
1_10
WATER HAMMER
Disables the water hammer function.
Enables the water hammer function during opening to help electric lock release.
Operation:
at the START command, the following will occur in sequence:
- electric lock activation;
- closing pulse of
1 sec
;
- opening;
- electric lock release after
2 sec
.
ON
OFF
10 - DIP SWITCH DIP2
Deceleration speed equal to 50% of the maximum speed.
2_1
Deceleration speed equal to 30% of the maximum speed.
ON
DECELERATION
SPEED
OFF
Speed during normal movement equal to 100% of the maximum speed.
2_2
Speed during normal movement equal to 80% of the maximum speed.
ON
MOVEMENT SPEED
OFF
Enables fast closing function.
Operation: Reduces the stand-by time to 3 seconds following interception and
subsequent freeing of the photocells. Active only on photocell 1.
2_3
Fast closing disabled.
ON
FAST CLOSING
OFF
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Description
DIP
Status
Function
Description
DIP
Status
Function
changing this setting will
reset the control board and
a new learning cycle will be
required.
changing this setting will
reset the control board and
a new learning cycle will be
required.