24
BE12
UK
The gate does not move after a START
command.
Ÿ
Check that L3, L4 and L5 are off; if not, check the devices connected to
terminals 19-20-21.
Ÿ
Check fuses.
Ÿ
Check that the battery voltage is not below 11Vdc.
Ÿ
If L7 is blinking fast, learning procedure must be executed.
Transmitter range is short.
Check terminals 26-27 screws are tight.
Check and replace transmitter battery.
The gate does not fully open/close.
Check the motor connections.
The gate moves slowly.
Check the control board is not running on battery.
The gate moves slowly during opening.
The first maneuvre after a power failer is slowed and with automatic logic.
17 - TROUBLESHOOTING
Declaration of conformity CE
The manufacturer
eclares that the products
ELECTRONIC CONTROL UNIT BE12
are in conformity to the following CEE Directives
and that the following harmonised standards have been applied
:
GI.BI.DI.
Via Abetone Brennero, 177/B,
46025 Poggio Rusco (MN) ITALY
d
:
:
•
:
•
•
Date 10/10/2018
S.r.l.
Directive LVD 2006/95/CE and subsequent amendments
;
•
Directive EMC 2004/108/CE and subsequent amendments
;
EN60335-1,
EN61000-6-2, EN61000-6-3
The legal Representative
Michele Prandi
25
BE12
UK
Содержание AS06260
Страница 50: ...50 BE12 NOTE NOTES NOTES NOTAS ...