14
UK
BE12
• Red warning LEDs for N.C. contacts and for programming.
• Blue LED for times programming.
• Buttons on the circuit board for programming and learning the radio controls.
• Automatic run time learning with simplified procedure.
• Onboard radio receiver that can store up to 200 radio controls.
• Control of the radio transmitter channels via dip switches.
• Deceleration during opening and closing.
• Deceleration speed adjustable via DIP switch.
• Stop and motion inversion after intervention of the safety devices.
• Amperometric reading of motor absorption, adjustable via DIP switch.
• Pedestrian operation with motor 1 opening.
• Two N.C. inputs, photocell 1, photocell 2.
• One input (SAFETY) programmable as STOP or EDGE.
• Two possible operating logics: step-by-step with stop or condominium selectable via DIP switch.
• Gate phase shift time adjustable via DIP switch.
• Programming of automatic closing and pause time via DIP switch.
• Provision for use with buffer batteries.
• Soft-Start and Soft-Stop to limit mechanical shock.
2 - TECHNICAL SPECIFICATIONS/FUNCTIONS
1 - TECHNICAL SPECIFICATIONS
BE12 / AS06260
230 VAC single-phase 50/60 Hz
1-2
12 Vdc
12 Vdc 10W max
Integrated, 200 trasmitters maximum
-20°C +60°C
TIME
12 Vdc 10W max
Electronic control unit for automation
of a double swing gate with 12VDC motors
Control unit
Power supply
No. of motors
Motor power supply
Flashlight
Radio receiver
Operating temperature
Run time
Accessory power supply
Type
WARNINGS:
This product has been tested by GI.BI.DI. for full compliance with the requirements of the directives in force. GI.BI.DI. S.r.l. reserves
the right to change the technical data without prior notice in relation to product development.
READ CAREFULLY THESE INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION.
Thank you for choosing GIBIDI.
DISPOSAL:
GI.BI.DI. advises recycling the plastic components and to dispose of them at special authorised
centres for electronic components thus protecting the environment from polluting substances.
UK
15
UK
BE12
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
It is important for the safety of persons to follow these instructions.
Keep this instruction manual.
3 - INSTALLATION WARNINGS
4 - WARNINGS FOR THE USER
• In the event of an operating fault or failure, cut the power upstream of the control unit and call
Technical Service. Periodically check functioning of the safety devices. Any repairs must be carried out by
specialised personnel using original and certified materials.
• The product may not be used by children or persons with reduced physical, sensorial or mental capacities,
or lacking experience and knowledge, unless appropriately instructed.
• Do not access the circuit board for adjustments and/or maintenance.
• Before proceeding with installation, fit a differential magnetothermal switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening
distance of at least 3mm.
To prevent possible interference, differentiate and always keep the power cables (minimum cross-section
1.5 mm²) separate from the signal cables (minimum cross-section 0.5 mm²).
Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that are connected to the same N.C. (normally closed) input, and in parallel all
the devices that share the same N.O. (normally open) input.
Incorrect installation or improper use of the product may compromise system safety.
Keep all the materials contained in the packaging away from children since they pose a potential hazard.
The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used.
When installation is complete, always carefully check proper functioning of the system and the devices used.
This instruction manual addresses professionals qualified to install “live equipment” and therefore requires
good technical knowledge and installation in compliance with the regulations in force.
Maintenance must be carried out by qualified personnel.
Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
The control unit described in this document may only be used for the purpose for which it was designed.
Check the intended end use and take all the necessary safety precautions.
Use of the products for purposes different from the intended use has not been tested by the manufacturer and
is therefore on full responsibility of the installer.
Mark the automated device with visible warning plates.
Warn the user that children or animals should not play or stand near the gate.
Appropriately protect the dangerous points (for example, using a sensitive frame).
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Содержание AS06260
Страница 50: ...50 BE12 NOTE NOTES NOTES NOTAS ...
Страница 51: ...51 BE12 NOTE NOTES NOTES NOTAS ...