PeakStore5 Manual Version 3.0
19
6.1.5. Measurement Protocol Template
Picture 16: configuration menu measurement protocol template
A measurement protocol template can be chosen from a pool of templates. The templates of
type
(Drawing)
contains a drawing surface where a schema of the machine can be drawn by
hand. The data type
(Picture)
contains a preset machine schema picture. Templates with the
data type
(Empty)
omits the sensor overview completely. The following templates are availa-
ble:
•
2 Spur gear stage + Planetary stage
•
3 Spur gear stage
•
4 Spur gear stage + Planetary stage
•
A60-B130
•
Blade bearing
•
Motor
•
Planetary stage + 2 Spur gear stage
•
Motor
•
Motor + Gear box
•
T Gear box + Generator
•
Empty Template
Additionally, the sensor positions can be placed beforehand if the selected protocol is of the
type
(Picture)
. These are then used in each measurement with this configuration. At first the
check "Activate automatic sensor placement" must be set. The desired position has to be
clicked to place the sensor. If an already placed sensor is clicked again, a popup will open to
change the measurement position and direction.