18
X2: Door safety switch
You can connect a door safety switch for a pass door or a
slack-rope switch to terminals X2.1/2.2.
▪
Install the product according to the manufacturer‘s instructions.
▪
Connect the product as shown.
With the door safety switch open and simultaneousmovement
command, the door stops, and fault indication
F 1.2
appears.
X3: Emergency stop switch
You can connect an emergency stop switch to terminals
X3.1/3.2:
▪
Install the product according to the manufacturer‘s instructions.
▪
Connect the product as shown.
If you are operating a door drive unit with a frequency inverter,
you cannot operate the door control until 30 seconds after the
emergency stop switch has been released. During this time,
the display of the door control flashes.
When activating the emergency stop switch fault indication
F 1.4.
appears.