31
1.7/1.8 Switching position of relays X20/X21
You only have to teach-in this switching position if you want to
use the options
.1
/
.2
or
1. 1
of menu item
2.7
or
2.8
.
With this menu item you can set the door position in which
relays X20 and X21 switch. To use this function, you must set
menu item P 2.7/P 2.8 and connect a device to X20 and/or X21.
Door movement without function of the safety devices!
▪
Block the door for pedestrians and vehicles while adjusting.
1.7
Setting the switching position of relay X20
1.8
Setting the switching position of relay X21
▪
Move to the desired door position using the
OPEN or CLOSE button
.
▪
Save the door position by pressing the
STOP button
once.
2.1 Safety edge in pre-limit area
Use this menu item to activate or deactivate the safety edge
in the pre-limit area. The pre-limit area will be calculated
automatically, it is maximum 50mm (1.96“).
2.1
Safety edge in pre-limit area
►
. 1
Activated.
.2
Deactivated.