Operating instructions SG 160
9 Fusion data
49
Guidelines for heating element socket fusion of pipes and piping
components of PVDF
at an ambient temperature of 20 °C and
moderate air movement.
Heater temperature 260 °C
±±±±
10 °C
1
2
3
4
5
6
Pipe outer
diameter
min.
Heat soak
Changeover
Cooling
wall
thickness
mm
s
(Maximum time)
s
fixed
s
total
min
d in mm
16
1.5
4
4
6
2
20
1.9
6
25
1.9
8
32
2.4
10
4
12
4
40
2.4
12
50
3.0
18
63
3.0
20
6
18
6
75
3.0
22
90
3.0
25
110
3.0
30
6
24
8