DryLoc pH/ORP Sensor Electronics

Mfr. Part No.

Code

Description

3-2750-1

159 000 744

In-line Sensor Electronics with Junction Box

3-2750-2

159 000 745

In-line Sensor Electronics with Junction Box and EasyCal

3-2750-3

159 000 746

Submersible Sensor Electronics with 4.6 m (15 ft) cable, 

¾

 in. NPT threads

3-2750-4

159 000 842

Submersible Sensor Electronics with 4.6 m (15 ft) cable, ISO 7-1/R

¾

 threads

3-2750-7

159 001 671

In-line Sensor Electronics, Digital (S

3

L), with 4.6 m (15 ft) cable, 

¾

 in. NPT threads

3-2750-8

In-line Sensor Electronics, with 4.6 m (15 ft) cable,  ISO 7-1/R

¾

 threads 

(Special Order Only)

Ordering Information

Parts and Accessories

3-0700.390

198 864 403

pH Buffer Kit

3-2700.395

159 001 605

Calibration kit: included 3 PP cups, cup stand, 1 pint pH 4.01, 1 pint pH 7.00

3-2759

159 000 762

pH/ORP Simulator/System tester

3-2759.391

159 000 764

Adapter cable to connect 2759 and 2750

3-8050-1

159 000 753

Universal Mount Junction Box

3-8050-2

159 000 754

Universal Mount Junction Box with EasyCal 

3-8052-1

159 000 755

¾

 in. NPT mount Junction Box

3-8052-2

159 000 756

¾

 in. NPT mount Junction Box with EasyCal

3-9900.392-1

159 000 839

Liquid tight connector kit, NPT (1 connector)

3-9900.392-2

159 000 840

Liquid tight connector kit, PG 13.5 (1 connector)

3822-7004

159 001 581

pH 4.01 buffer solution, 1 pint (473 ml) bottle

3822-7007

159 001 582

pH 7.00 buffer solution, 1 pint (473 ml) bottle

3822-7010

159 001 583

pH 10.00 buffer solution, 1 pint (473 ml) bottle

3822-7115

159 001 606

20 gram bottle Quinhydrone for ORP calibration

5523-0322

159 000 761

Cable, 3-con shield (blk/red/wht/shld) 22 AWG (per ft)

P31515-0P200

159 000 630

Universal Pipe Adapter PVC

P31515-0C200

159 000 631

Universal Pipe Adapter CPVC

P31515-0V200

159 000 459

Universal Pipe Adapter PVDF

3-8050.390-1

159 001 702

Retaining Nut Replacement Kit, NPT, Valox

®

3-8050.390-3

159 310 116

Retaining Nut Replacement Kit, NPT, PP

LED and Output Condition

Possible Causes

Suggested Solutions

Current Output: 

LED off, 

current output is 3.6 mA

Digital (S

3

L): 

Transmitter (8900 or 

9900) displays "Check Sensor"

•  No electrode installed.
•  Bad/dirty contacts between 

electrode and 2750.

• Install electrode.
•  Check interconnection between electrode and 2750, 

clean contacts, and/or lubricate sensor o-ring.

During EasyCal, the LED blinks 
rapidly for 4 seconds and the 
current output is frozen at a 
random fi xed value.

•  Buffer solution is outside of the 

accepted tolerance for the 2750.

•  The electrode is depleted 

(> 1.1 pH or 65 mV offset).

•  pH system: Use fresh 4 pH, 7 pH, or 10 pH buffer and 

restart the calibration.

•  ORP system: Use fresh 4 pH and 7 pH buffer solution 

saturated with Quinhydrone, or Light's Solution.

•  Clean or replace the electrode.

After completing calibration 
procedure, the output values 
are inaccurate.

• Insuf

fi

 cient time allowed for 

electrode stabilization during 
calibration.

Recalibrate:
•  Verify that test solutions are at room temperature 
•  Wait at least 30 seconds after placing electrode in 

solution before pressing S1 EasyCal button.

Troubleshooting

Содержание Signet 2750-1

Страница 1: ...4X Junction Boxes are integral parts of the in line versions 2750 1 2750 2 and 2750 7 and are available as accessories for the submersible versions 2750 3 and 2750 4 The optional EasyCal feature allow...

Страница 2: ...00 or 3K Balco temperature sensor versions for pH Operational Range 2750 0 00 to 14 00 pH 2000 mV ORP 0 C to 85 C 32 F to 185 F Response Time includes electrode response pH 6 s for 95 of change ORP ap...

Страница 3: ...A Signet installation fitting 12 7 mm to 101 6 mm 1 2 in to 4 in or a threaded tee is required to secure the electrode in the pipe The Signet Measurement and Instrumentation catalog offers a complete...

Страница 4: ...nts or their vapor may lead to failure of the retaining nut ejection of the sensor and loss of the process fluid with possibly serious consequences such as damage to equipment and serious personal inj...

Страница 5: ...othing when working with chemicals in pressurized pipe Locked The molded alignment marks are enhanced for clarity 2750 In Line Assembly 1 Insert electrode into base of the 2750 3 or 2750 4 and turn un...

Страница 6: ...00 users If this direct wiring is used set the CALIBRATE menu to perform Calibration at INSTRUMENT Connect the terminals as shown to any digital S3 L terminals 8900 and 9900 users If using EasyCal set...

Страница 7: ...consequence For pH calibration use any two of these international standards pH 4 0 7 0 or 10 0 buffer solutions Signet part number 3 0700 390 contains one capsule of each value To produce standards f...

Страница 8: ...tor kit PG 13 5 1 connector 3822 7004 159 001 581 pH 4 01 buffer solution 1 pint 473 ml bottle 3822 7007 159 001 582 pH 7 00 buffer solution 1 pint 473 ml bottle 3822 7010 159 001 583 pH 10 00 buffer...

Отзывы: