background image

 

 

 

PRODUCT SHEET 

[email protected] 

[email protected]

 

www.biopac.com 

 

 

BIOPAC Hardware   |   

BioNomadix Series

   |   Page 1 - 26 

 

Updated: 8.18.2020

 

BIONOMADIX SERIES 

The BioNomadix system is a wireless, multi-channel physiological recording 
platform. Its untethered design allows for nearly unlimited freedom of movement 
and unsurpassed comfort, enabling subjects to easily relax into their protocol. 
There are twelve different BioNomadix modules sets, each consisting of a 
matched transmitter and receiver specifically optimized for desired physiological 
signals. Multiple BioNomadix module sets (typically eight maximum) can be used 
to create a customized BioNomadix system. 

Each BioNomadix module set is capable of recording of two independent channels, with the exception of the 
Accelerometer module, which records three channels. 

BIONOMADIX TRANSMITTER AND RECEIVER SETS 

 

BN-ACCL3   BioNomadix Accelerometer  

 

BN-ECG2   BioNomadix 2-Channel ECG 

 

BN-EEG2   BioNomadix 2-Channel EEG 

 

BN- EGG2   BioNomadix 2-Channel EGG 

 

BN- EMG2   BioNomadix 2-Channel EMG 

 

BN- PPGED  BioNomadix PPG and EDA 

 

BN-GONIO   BioNomadix 2-Channel Goniometry  

 

BN-DYNEMG BioNomadix Dynamometry and EMG 

 

BN- EOG2  BioNomadix 2-Channel EOG  

 

BN-NICO  BioNomadix Cardiac Output  
BN-RSP2  BioNomadix 2-Channel Respiration  
BN-RSPEC BioNomadix RSP and ECG  
BN-SKT2  BioNomadix 2-Channel Skin Temp 

 

BN-STRIKE BioNomadix 2-Channel Heel/Toe Strike 

 

BioNomadi

BN-GYRO-75

 and 

BN-GYRO-300

 Angular Rate Sensors are 

discontinued items

. 

BIONOMADIX TRANSMITTER ONLY 

 

BN-ACCL3-T    Accelerometer  

 

BN-ECG2-T     2-Channel ECG 

 

BN-EEG2-T     2-Channel EEG 

  

 

BN- EGG2-T    2-Channel EGG 

 

BN- EMG2-T    2-Channel EMG 

 

BN- PPGED-T  PPG and EDA 

 

BN-GONIO-T   Goniometry 

BN-DYNEMG-T    Dynamometry and EMG 
BN- EOG2-T       2-Channel EOG 
BN-NICO-T  

   Cardiac Output 

BN-RSP2-T  

   2-Channel Respiration 

BN-RSPEC-T     RSP and ECG  
BN-SKT2-T 

   2-Channel Skin Temp 

BN-STRIKE-T     2-Channel Heel/Toe Strike 

 

Click to view a 

BioNomadix System Diagram

. 

BIONOMADIX LOGGER (BN-LOGGER)  

Get the real-world data your application demands! 

BioNomadix Loggers wirelessly record physiological data as subjects freely and naturally live their lives—record 
from up to three dual-channel wearable BioNomadix Transmitters

*

 plus a built-in accelerometer. Sync the 

BioNomadix Logger with GPS for a correlation between physiological and location data. 

Use as a stand-alone system with Acq

Knowledge

 or combine with BioNomadix Receivers and a computer 

running Acq

Knowledge

 

  Sync Transmitters to the Logger mode for remote data logging. 

 

 Combine Transmitters with BioNomadix wireless Receivers to 

operate in the lab for real-time telemetry.  

The compact Logger device provides a color display for visual 
feedback, speaker for auditory feedback, vibration for haptic feedback, 
voice journal for participant comments, event markers, and alarms. 
Includes micro-USB to USB cable for charging/data transfer, AC 
Charger and belt case. 

Existing BioNomadix devices require a firmware upgrade to be 

  compatible with Loggers—see BN-TX-UPG online for details.

  

NOTE:

 BioNomadix Logger requires Acq

Knowledge

 software version 4.4.1 or higher. 

Содержание BioNomadix Series

Страница 1: ...nsors are discontinued items BIONOMADIX TRANSMITTER ONLY BN ACCL3 T Accelerometer BN ECG2 T 2 Channel ECG BN EEG2 T 2 Channel EEG BN EGG2 T 2 Channel EGG BN EMG2 T 2 Channel EMG BN PPGED T PPG and EDA BN GONIO T Goniometry BN DYNEMG T Dynamometry and EMG BN EOG2 T 2 Channel EOG BN NICO T Cardiac Output BN RSP2 T 2 Channel Respiration BN RSPEC T RSP and ECG BN SKT2 T 2 Channel Skin Temp BN STRIKE T...

Страница 2: ...m Touchproof leads to BN Transmitter BN ADAPT 3 Adapter 3 x 10 cm for connecting 1 5 mm Touchproof leads to BN Transmitter BIONOMADIX TRANSDUCERS use with wireless and Smart Amplifiers BN PULSE XDCR Pulse Transducer for BioNomadix BN PPGED or Smart Amplifier PPG100D BN PULSEEAR XDR Pulse Earclip Transducer for BioNomadix BN PPGED or Smart Amplifier PPG100D BN RESP XDCR Respiration Transducer for B...

Страница 3: ...ality of the data and makes it much easier for subjects to respond naturally Available sizes extra small small medium large and extra large see sizing dimensions below 22 pockets 2 neck front 2 neck back 4 chest center 4 back center 2 hip front 2 hip back 3 left arm 3 right arm 4 zippers right front from arm to hip left back from shoulder to hip right and left under arm from neck front to neck bac...

Страница 4: ...eart rate respiration rate Heart rate variability HRV Respiratory Sinus Arrhythmia RSA etc Combine with the Logger GPS tracker and other wireless sensing devices for comprehensive analysis of your subject s experience The Logger s accelerometer can provide activity information the GPS will provide a history of a subject s movements Sized separately for men and women for a snug fit below the bust t...

Страница 5: ...ple transmitters The BioNomadix Shirt incorporates zippered openings for positioning electrode leads properly The BioNomadix BioShirt has one pocket for use with a BN RSPEC Respiration and ECG Transmitter and smart electrodes woven into the fabric 4 Set the power switch on the BioNomadix Transmitter to ON The Status light will flash sequences based upon connectivity and battery life 5 Double blink...

Страница 6: ...s can use factory presets Calibration is an advanced procedure TRANSMITTER BATTERY LIFE Transmitter battery life is described below as a change of color in the sequence of LED flashes LED Color Pattern Charge green green green green 75 100 yellow green green green 50 75 yellow yellow green green 25 50 yellow yellow yellow green 5 25 yellow yellow yellow yellow 5 IMPORTANT If the transmitter is to ...

Страница 7: ... of 1 0 Hz to 500 Hz 0 9 µV rms bandwidth of 0 005 Hz to 100 Hz Input Voltage Range up to 10 mV P P up to 2 mV P P up to 10 mV P P up to 10 mV P P up to 10 mV P P Output Voltage Range 10 V receiver output CMRR 110 dB typical at 50 60Hz 90dB minimum for ECG EEG EMG and EOG 100 db minimum for EGG CMII 1000 MΩ 50 60 Hz Differential Input Impedance 2 MΩ Fixed Gain 2 000 10 000 2 000 2 000 2 000 Operat...

Страница 8: ...OFF Resolution 0 01 C rms FSR 4096 4 88 mV 0 01 rotation rms N A Signal range 13 to 51 C 10 V at output 180 10 V at output Output Voltage range 10 V receiver output Operating time 72 90 hours Included strap 137 cm BN STRAP 137 137 cm BN STRAP 137 76 cm BN STRAP 76 BN STRAP 33 33 cm BN STRAP 33 Input BN TEMP A B XDCR BN RESP XDCR BN GON 110 XDCR BN GON 150 XDCR BN GON F XDCR BN TOR 100 XDCR BN TOR ...

Страница 9: ...0 Hz Dyn DC 3 Hz 10 Hz or 100 Hz LP EMG see BN EMG2 specs Notch filter 50 60 Hz user controlled switch typically not required factory preset OFF See Appendix for additional hardware specific output options Resolution see BN RSP2 and BN ECG2 specs PPG FSR 4096 4 88 mV EDA 0 012 µS min step Z nominally 0 05 Ω rms at 10 Hz BW dZ dt 0 0075 Ω sec rms at 10 Hz BW Dyn 35 micro kg f cm2 0 0005 psi rms EMG...

Страница 10: ... MP Research System or with isolated power supply IPS100C for 3rd party data acquisition system Battery Charger BioNomadix transmitters use an L ion battery full charge takes approx 1 hour to provide maximum operating time A battery charger is included with each module pair See BN CHRG for charge time and recharge cycle details Compliance FCC IC FCC Part 15 B FCC ID receiver ZWIBNXR1 transmitter Z...

Страница 11: ...input for each BioNomadix unit 3 LEAD BIONOMADIX ELECTRODES LEADS also for biopotential Smart Amplifiers Lead wires 3 red white and black Electrode clips 3 Length BN EL15 LEAD3 15 cm BN EL30 LEAD3 30 cm BN EL45 LEAD3 45 cm Interface Primary and secondary channel lead for the following BioNomadix Transmitters BN ECG2 BN EEG2 BN EGG2 BN EMG2 BN EOG2 Do not use for EDA or NICO 4 LEAD BIONOMADIX ELECT...

Страница 12: ...interference multi path or radio frequency signal blocking In the event of a communications failure BioNomadix Tx and Rx modules will attempt to re establish communications until such communications can be re established BioNomadix Tx are purposely kept at very low power so as not to disrupt the sensitive biophysical parameter measured to enhance battery life and to satisfy the relevant FCC regula...

Страница 13: ...tor Wavelength 890 nm nominal maximum Optical Low Pass Filter Cutoff ambient visible light filter The transducer operates with the BioNomadix Pulse Transmitter BN PPGED and consists of a matched infrared emitter and photo diode which transmits changes in infrared reflectance resulting from varying blood flow Wavelength 800 1 000 nm 70 spectral response Nominal Output 20 mV peak peak Power 10 mA dr...

Страница 14: ... Active Area 12 7 mm diameter Interface BN STRIKE transmitter STRK A STRK B Skin Temperature Transducer BN TEMP A XDCR Nominal Resistance 2252 ohm at 25 C Maximum operating temperature 60 C Accuracy and Interchangeability 0 2 C Response Time 1 1 sec attached to skin Compatibility YSI series 400 temperature probes Sterilizable NO Not designed for immersion Cable 30 cm Dimensions 9 8 mm diameter x 3...

Страница 15: ...o biopac com support biopac com www biopac com BIOPAC Hardware BioNomadix Series Page 15 26 Updated 8 18 2020 Goniometer Torsiometer Transducers BN GON XDCR BN TOR XDCR BN GON F XDCR Use with BN GONIO Goniometry Module ...

Страница 16: ...ine Dry BioNomadix Strap Dimensions Length 20 cm 33 cm 76 cm 137 cm all widths 2 5 cm Material stretch Velcro hook loop type Use with BioNomadix Transmitters Length BN STRAP 20 20 cm BN STRAP 33 33 cm BN STRAP 76 76 cm BN STRAP 137 137 cm BioNomadix 10 20 EEG Cap System Attachment Ribbon cable 25 cm from cap to 19 Touchproof 1 5 mm sockets Material Lycra Use with BN EEG2 Lead adapters BN ADAPT TP2...

Страница 17: ...ized squeeze clip plug to mate with all BioNomadix Transmitters Weight 142 grams 5 oz Dimensions 75 mm x 51 mm x 40 mm Lithium Ion Chemistry Termination algorithm CCCV Termination indicated Current falls to limit value 5 Top off charge 1 hour or current falls to limit value 10 Restart threshold 7 8 of termination voltage or every 2 hours Maintenance charge N A Charge voltage limit Preset to 4 20 V...

Страница 18: ...se interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Conformément à la réglementation d Industrie Canada le présent émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage radioélectriqu...

Страница 19: ...clips will be required to calibrate a Biopotential Transmitter Receiver set 1 Attach alligator clip to LEAD side of electrode pinch clip see figure on right 2 Connect black and white pinch clips together this combination is attached to signal generator ground 3 Connect red pinch clip to signal generator output for the Transmitter Receiver set ECG EGG EMG EOG The signal generator should be set to 1...

Страница 20: ...lished by introducing a known and varying resistance that can be precisely set to a specific rate of change For calibration related to cardiac output measurements a varying resistance of 1 ohms seconds to 5 ohms second is ideal A photonically isolated voltage controlled resistance can be used for this calibration A cadmium sulfide cell in parallel with a resistance of 25 ohms can be employed in co...

Страница 21: ...set for the various data acquisition platforms however excitation voltages are user adjustable on the DA100C Recommended excitation is 5VDC 1 Place goniometer with care to verify that limb joint torso attachment will not result in over stretch at the limits of limb joint torso movement 2 Put body in the first position which brackets one end of range of movement Press CAL 1 3 Put body in the second...

Страница 22: ...de a 5 V output and a 1 G input will provide a 5 V output when properly scaled The BN ACCL has a factory default of 16 G Use the DIP switches on the side of the BN ACCL Receiver Module to set the Transmitter to the desired range If the range needs to be set to something other than 16 G perform the following steps prior to calibration using Earth s gravity as described in the previous paragraph 1 I...

Страница 23: ... if Alternative Signal is enabled UP ECG2 R BioNomadix Receiver indicates Factory Preset EMG2 R BioNomadix Receiver Filter Option Switch Number Filter Option Switch Number High Pass SW3 High Pass SW3 0 05 Hz HP DOWN 5 Hz HP DOWN 1 Hz HP UP 10 Hz HP UP Low Pass SW4 Low Pass SW4 35 Hz LP UP 250 Hz LP UP 150 Hz LP DOWN 500 Hz LP DOWN EEG2 R BioNomadix Receiver EOG2 R BioNomadix Receiver Filter Option...

Страница 24: ... CH A ECG CH B Low Pass SW6 SW4 1 Hz LP UP 35 Hz LP UP 10 Hz LP DOWN 150 Hz LP DOWN High Pass SW7 SW3 0 5 Hz HP UP 1 Hz HP UP DC DOWN 0 05 Hz HP DOWN NICO R BioNomadix Receiver Filter Option Switch Number Low Pass SW1 Z CH SW2 dZ CH 5 Hz LP UP UP Low Pass SW3 Z CH SW4 dZ CH 3 Hz LP UP UP Low Pass SW5 ZCH SW6 dZ CH 1 Hz LP UP UP DC to 50 Hz DOWN for all switches Bandlimited to 10 Hz in BN NICO unit...

Страница 25: ...arning Alternative signal replaces the raw signal To display raw and processed signal alternative s use AcqKnowledge calculation channels ECG2 R and RSPEC R BioNomadix Receivers EOG2 R BioNomadix Receiver Signal Output SW5 Signal Output SW5 ECG Factory Preset DOWN EOG Factory Preset DOWN Heart Rate Alternative Signal UP Derivative Alternative Signal UP EEG2 R BioNomadix Receiver Signal Output SW5 ...

Страница 26: ... UP 4375 μS DOWN UP UP 3750 μS UP DOWN UP 3125 μS DOWN DOWN UP 2500 μS UP UP DOWN 1875 μS DOWN UP DOWN 1875 μS UP DOWN DOWN 625 μS DOWN DOWN DOWN Range G Mode or Threshold Tap Mode SW4 SW5 2 G UP UP 4 G DOWN UP 6 G UP DOWN 8 G DOWN DOWN GONIO R BioNomadix Receiver Filter Option CH A CH B Low Pass SW3 SW5 3 Hz LP UP 3 Hz LP UP 100 Hz LP DOWN 100 Hz LP DOWN SW4 SW6 10 Hz LP UP 10 Hz LP UP 100 Hz LP ...

Отзывы: