3.

  Unlock the ring on base of 2750 (The ring is unlocked when 

the lines on the ring and body of the 2750 are not aligned.)

4.

  Place 2750 onto top of electrode and turn 

until the assembly drops into position.

5. 

Turn locking ring 

1

/

4

 turn to secure the 2750 assembly. 

 

(The ring is locked when the line on the ring and 
the line on the body of the 2750 are aligned.)

NOTE:

Keep the electrical interconnection between electrode and 
sensor electronics dry and clean at all times.

In-Line Sensor and Electrode Removal

• 

To remove electronics assembly only: 

Turn locking ring 

1

/

4

 turn; lift assembly straight up.

• 

To remove electrode from the pipe: 

Remove electronics assembly, then unthread retaining nut; pull electrode straight up.

• 

To remove the complete 2750 system: 

Hold locking ring in place. Unthread retaining nut and pull electrode straight up.

CAUTION!

•  Do not remove the electrode from a pressurized pipe.
•  Wear appropriate protective clothing when working with chemicals in pressurized pipe.

Locked

The molded alignment marks 
are enhanced for clarity.

2750 In-Line Assembly

1.

  Insert electrode into base of the 

2750-3 or 2750-4 and turn until 
keyed contacts are seated.

NOTE:

 Lubricate O-ring if 

installing sensor is dif

fi

 cult.

2.

  Thread retaining nut over 

electrode and hand-tighten 
onto 2750.

3.

 Attach 

¾

 in. watertight pipe to the top of the 2750.

 

Secure the threaded connection to prevent any leakage.

   

*

 For additional defense against possible accumulation 

of condensation at the back seal area of the sensor, 

fi

 ll 

the lower 75 mm to 100 mm (3 in. to 4 in.) of conduit or 
extension pipe with a 

fl

 exible sealant such as silicone.

NOTE:

Keep the electrical interconnection 
between electrode and sensor 
electronics dry and clean at all times.

2750-3: ¾ in. NPT threads
2750-4: ISO 7-1/R

¾

 threads

Lubricate O-rings with a 
non-petroleum based, viscous 
lubricant (grease) compatible 
with the system.

2750-3, 2750-4 Submersible Installation

221 mm 

(8.7 in.)

Unlocked

The molded alignment 
marks are enhanced 
for clarity.

Locking Ring

LUBRICATE O-RINGS WITH A NON-PETROLEUM BASED, 
VISCOUS LUBRICANT (GREASE) COMPATIBLE WITH THE SYSTEM.

Содержание Signet 2750-1

Страница 1: ...4X Junction Boxes are integral parts of the in line versions 2750 1 2750 2 and 2750 7 and are available as accessories for the submersible versions 2750 3 and 2750 4 The optional EasyCal feature allow...

Страница 2: ...00 or 3K Balco temperature sensor versions for pH Operational Range 2750 0 00 to 14 00 pH 2000 mV ORP 0 C to 85 C 32 F to 185 F Response Time includes electrode response pH 6 s for 95 of change ORP ap...

Страница 3: ...A Signet installation fitting 12 7 mm to 101 6 mm 1 2 in to 4 in or a threaded tee is required to secure the electrode in the pipe The Signet Measurement and Instrumentation catalog offers a complete...

Страница 4: ...nts or their vapor may lead to failure of the retaining nut ejection of the sensor and loss of the process fluid with possibly serious consequences such as damage to equipment and serious personal inj...

Страница 5: ...othing when working with chemicals in pressurized pipe Locked The molded alignment marks are enhanced for clarity 2750 In Line Assembly 1 Insert electrode into base of the 2750 3 or 2750 4 and turn un...

Страница 6: ...00 users If this direct wiring is used set the CALIBRATE menu to perform Calibration at INSTRUMENT Connect the terminals as shown to any digital S3 L terminals 8900 and 9900 users If using EasyCal set...

Страница 7: ...consequence For pH calibration use any two of these international standards pH 4 0 7 0 or 10 0 buffer solutions Signet part number 3 0700 390 contains one capsule of each value To produce standards f...

Страница 8: ...tor kit PG 13 5 1 connector 3822 7004 159 001 581 pH 4 01 buffer solution 1 pint 473 ml bottle 3822 7007 159 001 582 pH 7 00 buffer solution 1 pint 473 ml bottle 3822 7010 159 001 583 pH 10 00 buffer...

Отзывы: