26
‡
Connect
or
A
(3x)
5.2 Mounting kit with window
for DV DIASTAR DN 15–DN 150
5.2.1 Place the o-ring (1) in the slot provided
in the mounting kit (2).
5.2.2 Screw the mounting kit onto the DV-
DIASTAR
(Check the distance H,
see below)
.
5.2.3 Mount the needle (3) on DV DIASTAR
(For DN 100–150 place the needle
protector on the needle and then insert
in adapter).
5.2.4 Mount the DSR positioner (4) on the
adapter of the mounting kit (2) and
fasten with threaded studs (5).
Attention:
Make sure that the
connector A is vertically in line with the
connections on the DV DIASTAR.
5.2.5 Remove the lower protective plug (FC)
(6). Connect rapid connector (7) on
actuator and positioner.
5.2.6 Connect hose (8) between DV DIASTAR
and DSR positioner (connector A).
5.2.7 Connect air supply to connector P.
H
Window version
Diastar &
Mechanical check
Positioner
Area H
closed
DN 15 Gr. 2
50.7–52.7
DN 20 Gr. 2
55.4–56.3
DN 25 Gr. 2
54.2–57.6
DN 25 Gr. 3
54.7–56.8
DN 32 Gr. 3
56.3–57.7
DN 32 Gr. 4
48.7–58.3
DN 40 Gr. 4
51.9–54.5
DN 40 Gr. 5
51.7–54.0
DN 50 Gr. 4
56.1–57.9
DN 50 Gr. 5
53.3–56.8
DN 65
70.2–73.4
DN 80
75.3–76.9
DN 100
74.6–87.4
DN 150
76.5–87.4
All dimensions in mm
H = distance required for correct
installation of adapters
Connect
or
P