Clamp the stem (9) into the jaws of the
clamping device.
Use a suitable device to force the plug (23) into
the stem (1.).
Fix the plug in this position.
Insert the retaining ring (26) into the gap
between the stem and the plug (2.).
Use a screwdriver to force the retaining ring into
the groove in the stem (3.).
Slowly loosen the plug.
Take the stem out of the clamping device.
Installing inner parts
DANGER
Risk of bruises if the equipment or
component parts fall down.
Use suitable lifting gear when moving
or lifting the equipment and/or
component parts.
Make sure that the equipment cannot
topple over.
Make sure that nobody is standing
below the lifted equipment.
Attention!
Equipment may not work properly or get
damaged if parts are tilted or skewed
when installed.
Use suitable lifting gear to mount the
component parts.
Do not tilt or skew the component
parts during installation.
During installation make sure that the
component parts are not damaged by
physical shocks.
The required bearing capacity of the lifting gear
depends on the equipment type. Contact the
manufacturer for more information on the weights
of the individual parts.
Assemble the shown nozzle parts outside the valve
body.
Содержание ZK 313
Страница 1: ...Control Valve ZK 313 Original Installation Instructions 818542 04 ...
Страница 55: ...55 Fluid flowrate and differential pressure Flowrates cold water A Differential pressure B Flowrate ...
Страница 56: ...56 KVS value CV value 1 1 1 2 2 1 5 1 7 3 2 3 2 7 4 3 6 4 2 5 5 5 6 4 6 8 9 4 7 11 12 7 8 13 15 0 9 20 23 1 ...