32
LRG 1x-6x - Installation & Operating Manual -
819878-00
Installation
3.
If necessary, apply a small quantity of silicone grease (e.g. Molykote® III) to the electrode thread
I
.
4.
Screw the conductivity electrode into the threaded standpipe of the tank or flange cover, and tighten
securely using a torque wrench (with size 41 open-ended spanner attachment).
Tightening torque when cold:
■
■
LRG 16-60/LRG 16-61/LRG 17-60 = 250 Nm
Installation examples with dimensions, see Fig. 14, Fig. 15, Fig. 16, from page 33