Administrator Mode
4
[Region of Interest]
Defines clarity and sets privacy mask to different parts of the live view for the camera
connecting to third-party software through ONVIF/RTSP. This function is disabled by default.
Select Enable and click ROI Setting to configure:
1. On the popup window, use your mouse and draw directly on the live view to specify a
region.
Figure 4-3
2. To define clarity to the region, select
ROI
and select
High
,
Medium
or
Low
using the
drop-down list.
3. To set a Privacy Mask, select
Privacy Mask
and select a color using the drop-down list.
4. Click
Apply
to apply the configurations.
[GOP Structure and Length]
Use the
Group of Picture(GOP) Size
drop-down list to set the number of seconds between
every key frame. This option is only available when H.264 is selected for codec.
[Record Settings]
The alarm settings allow you to capture images before and/or after the motion or I/O event
happens.
Pre-alarm recording time:
Activates video recording before an event occurs. Set the
recording time to 1 or 2 seconds. The recording is saved in the buffer of the camera.
Post-alarm recording time:
Activates video recording onto the inserted memory card
after an event occurs. Set the recording time from 1 to 30 seconds.
Split Interval (Max. Video Clip):
Sets the maximum time length of each recorded file
from 1 to 5 minutes.