(Specially for application to level measurement)
The input-output range adjustment enables you to
change automatically the measurement range by re-
adjusting the lower limit of the measurement (LRV) or
the upper limit of the measurement (URV).
, /59$GM =HUR DGMXVWPHQW E\ FKDQJLQJ WKH
UDQJH/59/59DGMXVWPHQW
3UHVVWKH
key on the screen
c
to select the LRV
adjustment mode.
The measured value and unit on the screen
d
are
WKHVDPHDVWKRVHLQWKHQRUPDOPRGHDQG³ĸ´DQG
“ZERO” light up.
$SSO\ WKH UHIHUHQFH SUHVVXUH IRU /59 P$ RQ WKH
screen
d
. After checking the measured value corre-
sponding to 4 mA, press the key.
³=(52´EOLQNVRQWKHVFUHHQ
e
. Press the key on
the screen
e
to perform a zero adjustment at the in-
put pressure.
Settable range:
±/591RWH
6HOHFW ZKHWKHU WKH /59 DGMXVWPHQW YDOXH VHWWLQJ LV
saved on the screen
g
.
Press the key to save the LRV adjustment value
setting and return to the screen
d
.
Press the or key to cancel the setting and return
to the screen
d
.
&KHFNWKDWWKH]HURDGMXVWPHQW/59ZDVSHUIRUPHG
as intended on the screen
d
.
Press the key to perform a zero adjustment again.
Press the or key to move to the next screen for
item name selection.