Operator's Manual
First Edition • Seventh Printing
Controls
24 ZX-135/70
Part No. 160567
4
Primary boom up/down buttons
Press the primary boom up button and the
boom will raise. Press the primary boom down
button and the boom will lower.
5
LCD screen control buttons
6
Engine speed select button
Press the engine speed select button to select
the engine speed. When the arrow above the
rabbit is lit, the engine is in high idle speed.
When the arrow above the turtle is lit, the
engine is in low idle speed.
7
LCD readout screen
a
low fuel indicator
b
engine oil pressure indicator
c
water temperature indicator
d
emergency power indicator
e
high engine rpm indicator
f
hour meter
8
Red Emergency Stop button
Push in the red Emergency Stop button to the
off position to stop all functions and turn the
engine off. Pull out the red Emergency Stop
button to the on position to operate the
machine.
9
Glow plug button (if equipped with manual
glow plugs)
Push the glow plug button and hold for 3 to
5 seconds.
10
Key switch for off/ground/platform selection
Turn the key switch to the off position and the
machine will be off. Turn the key switch to the
ground position and the ground controls will
operate. Turn the key switch to the platform
position and the platform controls will operate.
11
Engine start button
Press the engine start button to start the
engine.
12
Jib boom up/down buttons
Press the jib boom up button and the jib boom
will raise. Press the jib boom down button and
the jib boom will lower.
13
Platform level up/down buttons
Press the platform level up button and the
level of the platform will raise. Press the
platform level down button and the level of the
platform will lower.
14
Primary boom extend/retract buttons
Press the primary boom extend button and the
primary boom will extend. Press the primary
boom retract button and the primary boom will
retract.
15
20A circuit breaker for system circuit
16
Alarm
17
Bypass/recovery key switch
Bypass key position to be used only to level
the platform if the ground control display
shows platform out of level (P22) and platform
level controls do not work. Refer to the
operating instructions.
Recovery key position should be used only by
trained and authorized personnel.
a
b
c
d
e
f
Содержание X-135/70
Страница 9: ...First Edition Seventh Printing Operator s Manual General Safety Part No 160567 ZX 135 70 7 ...
Страница 11: ...First Edition Seventh Printing Operator s Manual General Safety Part No 160567 ZX 135 70 9 ...
Страница 12: ...Operator s Manual First Edition Seventh Printing General Safety 10 ZX 135 70 Part No 160567 ...
Страница 13: ...First Edition Seventh Printing Operator s Manual General Safety Part No 160567 ZX 135 70 11 ...