![Genie S Series Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/genie/s-series/s-series_maintenance-manual_2211875093.webp)
October 2018
Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1268489GT
S
®
B
ooms • Z
®
Booms
79
7 Lower the primary boom to 66°.
Result: The reading at the display and digital
level is within ± 2° of each other and of 66°.
Result: The reading at the display and digital
level is greater than ± 2° of each other and of
66°. The primary boom angle sensor must be
calibrated. Refer to Repair Procedure in the
appropriate Service and Repair Manual for
your machine,
How to Calibrate the Primary
Boom Angle Sensor
.
8 Lower the primary boom to 49°.
Result: The reading at the display and digital
level is within ± 2° of each other and of 49°.
Result: The reading at the display and digital
level is greater than ± 2° of each other and of
49°. The primary boom angle sensor must be
calibrated. Refer to Repair Procedure in the
appropriate Service and Repair Manual for
your machine,
How to Calibrate the Primary
Boom Angle Sensor
.
9 Lower the primary boom to 32°.
Result: The reading at the display and digital
level is within ± 2° of each other and of 32°.
Result: The reading at the display and digital
level is greater than ± 2° of each other and of
32°. The primary boom angle sensor must be
calibrated. Refer to Repair Procedure in the
appropriate Service and Repair Manual for
your machine,
How to Calibrate the Primary
Boom Angle Sensor
.
10 Lower the primary boom to 15°.
Result: The reading at the display and digital
level is within ± 2° of each other and of 15°.
Result: The reading at the display and digital
level is greater than ± 2° of each other and of
15°. The primary boom angle sensor must be
calibrated. Refer to Repair Procedure in the
appropriate Service and Repair Manual for
your machine,
How to Calibrate the Primary
Boom Angle Sensor
.
11 Fully lower the primary boom until it stops at
approximately -2.6°.
Result: The reading at the display and digital
level is within ± 2° of each other and of -2.6°.
Result: The reading at the display and digital
level is greater than ± 2° of each other and of
-2.6°. The primary boom angle sensor must be
calibrated. Refer to Repair Procedure in the
appropriate Service and Repair Manual for
your machine,
How to Calibrate the Primary
Boom Angle Sensor
.