October 2018
Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
45
Q-4
Inspect the Electrical Contactor -
DC / Bi-Energy Models
Genie specifications require that this procedure be
performed quarterly.
Maintaining the electrical contactor in good
condition is essential to safe machine performance.
Failure to locate a worn or damaged contactor
could result in unsafe operating conditions and may
cause component damage.
Z-30N, Z-33, Z-34, Z-40 and Z-45 models:
1 Remove the drive chassis cover from the
non-steer end of the machine and locate the
electrical contactor(s).
2 Locate the electrical contactor mounted on the
fuse bracket.
3 Visually inspect the contact points of the
contactor for the following items:
•
Excessive burns
•
Excessive arcs
•
Excessive pitting
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: Replace the contactor if any damage is
found.
Z-60 DC / FE models:
1 Open the turntable cover and remove the fuse
box cover.
1 fuse box
2 fuse box cover
2 Visually inspect the contact points of the
contactor for the following items:
•
Excessive burns
•
Excessive arcs
•
Excessive pitting
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: Replace the contactor if any damage is
found.