![Genie S Series Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/genie/s-series/s-series_maintenance-manual_2211875061.webp)
October 2018
Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
47
Q-7
Check the Generator Belts,
Pulleys and voltage - Bi-Energy
Models
Genie specifications require that this procedure be
performed quarterly.
Maintaining the generator belts and the pulleys is
essential to good generator performance and
service life. The generator will not operate properly
with loose or defective belts and continued use
may cause component damage.
Bodily injury hazard. Do not
inspect while the engine is
running. Remove the key to
secure from operation.
Bodily injury hazard. Beware of
hot engine components.
Contact with hot engine
components may cause severe
burns.
Note: Charging the batteries with the engine does
not fully charge the batteries. Periodically, use the
AC battery charger to fully charge the batteries.
1 Be sure that all fasteners and cables on the
generator are tight.
2 Remove the engine flywheel cover mounting
fasteners, then remove the cover.
3 Be sure that the pulley mounting fasteners are
tight and that the pulleys show no signs of
damage or unusual wear.
4 Check to be sure the engine pulley and the
generator pulley are aligned within
specification using a straightedge.
1 engine pulley
2 straightedge
3 maximum pulley offset
4 generator pulley
Note: If alignment does not meet specification,
Refer to Repair Procedure in the appropriate
Service and Repair Manual for your machine,
How
to Install the Engine Drive Pulley
to adjust the
pulley alignment.
Pulley alignment, maximum offset
0.0625 inch
1.58 mm
5 Inspect the generator belts for:
•
Cracking
•
Glazing
•
Separation
•
Breaks
6 Replace both belts if any damage is found.
Содержание S Series