![Genie S Series Скачать руководство пользователя страница 132](http://html.mh-extra.com/html/genie/s-series/s-series_maintenance-manual_2211875132.webp)
Maintenance Manual
October 2018
Annual Maintenance Procedures
118
S
®
Booms • Z
®
Booms
Part No. 1268489GT
1 Remove the boom end cover from the pivot
end of the boom.
1 boom end cover
2 side access covers
3 cable ends (located underneath the boom)
2 Remove the retaining fasteners from the
access covers located on the side of the boom
at the platform end of the machine. Remove
the covers.
3 Visually inspect the cables and components
through the inspection holes for the following:
•
Frayed or broken wire strands
•
Kinks or crushed cables
•
Corrosion
•
Paint or foreign materials on the cable
•
Split or cracked cable ends
•
Cables are on all sheaves
•
Cables have equal tension
•
Cables at end of adjustment range
•
Broken or damaged sheaves
•
Unusual or excessive wear
•
All fasteners in place and secure
Note: A flashlight and inspection mirror may be
necessary to thoroughly inspect the above items,
or an endoscope inspection camera.
Note: Refer to Maintenance Procedure P12-2,
Cable Replacement Criteria
.
Note: If required, the extend or retract cables must
be replaced as a set.
Note: If the boom extend or retract cables are
replaced, quarterly maintenance inspections must
be performed for the first year.
4 At the pivot end of the boom, visually inspect
for the following:
•
The red locking bracket is securely installed
over the cable adjustment bolts.
Содержание S Series
Страница 182: ......