![Genie S Series Скачать руководство пользователя страница 130](http://html.mh-extra.com/html/genie/s-series/s-series_maintenance-manual_2211875130.webp)
Maintenance Manual
October 2018
Annual Maintenance Procedures
116
S
®
Boo
ms • Z
®
Booms
Part No. 1268489GT
3
S-60, S-65, S-60X, S-60 XC, S-65 XC, S-60
TRAX, S-65 TRAX, S-80, S-85, S-80X, S-80
HF, S-85 HF, S-80 XC, S-85 XC:
Remove the
boom end cover from the pivot end of the
boom and set aside.
Note: S-60XC from S60XCH-45001 and
S60XCM-101, S-65 XC, S-80 HF, S-85 HF, S-80
XC and S-85 XC models.
The cable from the
length transducer can become damaged if it is
kinked or pinched.
S-60 HC:
Remove the boom end cover from
the pivot end of the boom while guiding the
small cable from the string potentiometer out
of the slot of the cover. Rest the cover and
string potentiometer on the counterweight.
Component damage hazard. The
cable from the string potentiometer
can become damaged if it is
kinked or pinched.
4 Remove the retaining fasteners from the
access covers located on the side of the boom
at the platform end of the machine. Remove
the covers.
5 Visually inspect the cables and components
through the inspection holes for the following:
•
Frayed or broken wire strands
•
Kinks in the cables
•
Corrosion
•
Paint or foreign materials on the cable
•
Split or cracked cable ends
•
Cables are on all sheaves
•
Extend cable break limit switch arm is
centered in the pivot plate
•
Cables have equal tension
•
Cables at end of adjustment range
•
Broken or damaged sheaves
•
Unusual or excessive wear
•
All fasteners in place and secure
•
S-60 HC:
String potentiometer cable break
limit switch arm is securely attached to end
of cable
Note: A flashlight and inspection mirror may be
necessary to thoroughly inspect the above items,
or an endoscope inspection camera..
Note: Refer to Maintenance Procedure P12-2,
Cable Replacement Criteria
.
Note: If required, the extend or retract cables must
be replaced as a set.
Note: If the boom extend or retract cables are
replaced, quarterly maintenance inspections must
be performed for the first year.
Содержание S Series