Programmed Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
143
Perkins Models
All Models:
•
Alternator and fan belts - replace
•
Engine valve lash – inspect/adjust
•
Engine crankcase breather - replace
403D-11, 404F-22
•
Turbocharger - inspect
804D-33
•
Alternator - inspect
•
Starting motor - inspect
•
Turbocharger - inspect
854F Models
•
Water pump - inspect
•
Engine crankcase breather - replace
Kubota Models
WG972
•
Spark plugs - replace
•
Coolant and vacuum lock hose of LPG
vaporizer - replace
•
Radiator coolant (L.L.C.) - replace
•
Cleaning water jacket and radiator interior
•
Valve clearance - check
•
Cleaning cylinder head
•
Valve seats - check
•
Air cleaner element - replace
•
Gasoline fuel hose and clamp bands -
replace
•
Carburetor and fuel tank inside - clean
Z482-E, D-1105
•
Fuel injection nozzle injection pressure -
check
P1-2
Replace the Drive Hub Oil
Drive hub specifications require that this procedure
be performed after the first 50 hours of operation.
After the initial oil replacement, specifications
require that this procedure be performed every
1000 hours.
Replacing the drive hub oil is essential for good
machine performance and service life. Failure to
replace the drive hub oil may cause the machine to
perform poorly and continued use may cause
component damage.
Drive Hubs:
1 Select the drive hub to be serviced. Drive the
machine until one of the two plugs is at the
lowest point.
2 Remove the plugs and drain the oil into a
suitable container.