October 2018
Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
57
Q-13
Test the Alarm Package (if
equipped)
Genie specifications require that this procedure be
performed quarterly.
The alarm package includes:
•
Travel alarm
•
Descent alarm
•
Flashing beacon
Alarms and a beacon are installed to alert
operators and ground personnel of machine
proximity and motion. The alarm package is
installed on the turntable covers.
Note: The alarms and beacon will operate with the
engine running or not running.
1 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
S-60 XC from S60XCH-45001 and
S60XCM-101, S-65 XC, S-80 HF, S-85 HF,
S-80 XC, S-85 XC, S-100, S-105, S-120,
S-125, S-100HD, S-120HD, SX-105 XC,
SX-125 XC, SX-135 XC, SX-150, SX-180,
Z-80/60, Z-135/70 and ZX-135/70 Models:
Result: The alarm should sound twice. The
flashing beacon should be on and flashing.
All other models:
Result: The flashing beacon should be on and
flashing.
All Models:
2 Activate the boom down function, hold for a
moment and then release it.
Result: The descent alarm should sound when
the down function is activated.
Complete this step for each boom that applies:
Primary, Secondary and Jib Booms.
3 Turn the key switch to platform controls.
Result: The flashing beacon should be on and
flashing.
4 Press down the foot switch. Activate the boom
down function, hold for a moment and then
release it.
Result: The descent alarm should sound when
the down function is activated.
Complete this step for each boom that applies:
Primary, Secondary and Jib Booms.
5 Press down the foot switch. Move the drive
control handle off center, hold for a moment
and then release it. Move the drive control
handle off center in the opposite direction,
hold for a moment and then release it.
Result: The travel alarm should sound when
the drive control handle is moved off center in
either direction.
Содержание S Series